©Quantum Research Group Ltd.
^R 0x12 - OSCILLOSCOPE
S
Bytes / Cmd 2nd Byte Range
YNC
Scope
1, 4, 16
1, 4, 16
Returns
0x12
0x00, 0x01
Put
Get
2
1
0x00, 0x01
n/a
Section 3.16, p. 11
Ctrl-R. In Put mode, controls the oscilloscope sync function
of Pin 43. The settings of this function are:
0: off {factory default}
1: on
When on, Pin 43 outputs a pulse that brackets the acquire
burst(s) for the keys targeted by scope. Without this it is
virtually impossible to view signals on an oscilloscope
corresponding to a specific key.
Pin 43 idles low and pulses high during a sync pulse.
^R is volatile, that is, it does not persist after a power down.
^W 0x17 - NOISE
Scope
SYNC
Bytes / Cmd Byte 2 Range
Returns
0x17
0x00, 0x01
Put
Get
-
-
2
1
0x00, 0x01
n/a
Section 3.14, p. 9
Ctrl-W. In Put mode, sets whether the noise sync feature is
enabled or disabled. The part must be in Put mode for this
command to work.
The settings are:
0: off {factory default}
1: on
This function has global scope. The default value is 0 (off).
In Get mode this function returns the current setting of ^W.
The setting of ^W does not become effective until the device
has been powered off and back on again or after the reset
(‘r’) command has been issued.
lQ
26
www.qprox.com QT60161B / R1.03