©Quantum Research Group Ltd.
Put Mode
Get Mode
Operand
Range
Bytes
Scope returned
Return
range
Default
setting
Char Hex
Name
Description
P/G Scope Bytes/Put
Returns
Page
Supervisory Commands
6
L
0x36
0x4C
Eeprom checksum
Lock references
returns checksum of internal eeprom
G
-
1
0x00..0xFF
18
24
-
-
locks reference levels into eeprom for future boundary
checks. ‘L’ must be followed by 0x00 (null) 100ms after
the command byte
P
16
2
1
0x00
0x00
0x4C
0x62
fully recalibrate keys;
b
l
0x62
0x6C
0x72
Recal keys
Return last command
Reset device
P
G
P
1, 4, 16
24
25
25
-
-
-
return byte is sent prior to calibration
send back last command byte received
-
1
0x00..0xFF
hard reset the device. ‘r’ must be followed by a null within
r
-
2
0x72
100ms.
V
0x56
0x57
Version
returns part version number
returns part signature number
G
G
-
-
1
1
0x00..0xFF
0x10
25
25
-
-
W
Signature
force device into Sleep mode. ‘Z’ must be followed by a
null within 100ms. 0x5A returned before and after
entering Sleep
0x5A,
0x5A
Z
0x5A
Sleep
P
-
-
2
2
0x00
25
-
sets the Master mode SPI clock rate and UART rate;
reset via ‘r’ command or hard reset to take effect
SPI: 93.75kHz, 187.5kHz, 750kHz, 3MHz
UART: 9.6k, 14.4k, 19.2k, 38.4k, 57.6k
0 (93.75k,
9600)
^Q
0x11
Data rate
P/G
0x00..0x04
0x11
-
1
0x00..0x04
25
oscilloscope sync control. 1 = on.
^R
0x12
0x17
Scope sync
Noise sync
P/G 1, 4, 64
G/P
2
2
0x00, 0x01
0x00, 0x01
0x12
0x17
-
-
1
1
0x00, 0x01
0x00, 0x01
0 (off)
0 (off)
26
26
feature is volatile - does not survive reset
noise sync enable; 1 = on
^W
-
device must be reset to take effect