QN8006B/8006LB
Table 11: Digital Audio Interface Timing Characteristics
Master Clock:
( Vcc = 2.7 ~ 5.0 V, TA = -25 ~ 85 oC, unless otherwise noticed. Typical values are at Vcc = 3.3V and TA = 25oC).
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNIT
fCLK_M
τrise_M
τfall_M
Ferr_M
Bus clock frequency
Rise-time
3.072
0.5
MHz
ns
Fall-time
0.5
ns
Frequency accuracy
According to PLL.
100
ppm
Slave Clock:
( Vcc = 2.7 ~ 5.0 V, TA = -25 ~ 85 oC, unless otherwise noticed. Typical values are at Vcc = 3.3V and TA = 25oC).
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNIT
fCLK_S
τrise_S
τfall_S
Ferr_S
Bus clock frequency
Rise-time
10
1.5
1.5
100
MHz
ns
Fall-time
ns
Frequency accuracy
ppm
Rev 2.08 (04/10)
Copyright ©2010 by Quintic Corporation
Page 16
Confidential A
Confidential Information contained herein is covered under Non-Disclosure Agreement (NDA).