 浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第27页浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第28页浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第29页浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第30页浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第32页浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第33页浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第34页浏览型号HYE18L256160BFX-7.5的Datasheet PDF文件第35页  
HY[B/E]18L256160B[C/F]X-7.5  
256-Mbit Mobile-RAM  
Functional Description  
2.4.8  
PRECHARGE  
The PRECHARGE command is used to deactivate  
(close) the open row in a particular bank or the open  
row in all banks. The bank(s) will be available for a  
subsequent row access a specified time (tRP) after the  
PRECHARGE command is issued. Input A10  
determines whether one or all banks are to be  
precharged, and in the case where only one bank is to  
be precharged, inputs BA0, BA1 select the bank.  
Otherwise BA0, BA1 are treated as “Don’t Care”.  
#,+  
#+%  
#3  
ꢌ(IGHꢍ  
2!3  
#!3  
7%  
Once a bank has been precharged, it is in the idle state  
and must be activated prior to any READ or WRITE  
commands being issued to that bank. A PRECHARGE  
command will be treated as a NOP if there is no open  
row in that bank, or if the previously open row is already  
in the process of precharging.  
!ꢂꢎ!ꢄ  
!ꢀꢀꢏ!ꢀꢁ  
!LL "ANKS  
!ꢀꢂ  
/NE "ANK  
"!ꢂꢏ"!ꢀ  
"!  
ꢒ $ONgT #ARE  
"! ꢒ "ANK ! RESS  
IF !ꢀꢂ ꢒ ,ꢏ OTHERWISE $ONgT #AREꢍ  
Figure 36 PRECHARGE Command  
2.4.8.1  
AUTO PRECHARGE  
Auto Precharge is a feature which performs the same individual-bank precharge functions described above, but  
without requiring an explicit command. This is accomplished by using A10 to enable Auto Precharge in conjunction  
with a specific READ or WRITE command. A precharge of the bank/row that is addressed with the READ or  
WRITE command is automatically performed upon completion of the READ or WRITE burst. Auto Precharge is  
non persistent in that it is either enabled or disabled for each individual READ or WRITE command. Auto  
Precharge ensures that the precharge is initiated at the earliest valid stage within a burst. The user must not issue  
another command to the same bank until the precharge (tRP) is completed. This is determined as if an explicit  
PRECHARGE command was issued at the earliest possible time, as described for each burst type.  
Table 12  
Timing Parameters for PRECHARGE  
Parameter  
Symbol  
- 7.5  
Units  
Notes  
min.  
45  
max.  
100k  
1)  
1)  
1)  
ACTIVE to PRECHARGE command period  
WRITE recovery time  
tRAS  
tWR  
tRP  
ns  
ns  
ns  
14  
PRECHARGE command period  
19  
1) These parameters account for the number of clock cycles and depend on the operating frequency as follows:  
no. of clock cycles = specified delay / clock period; round up to next integer.  
Data Sheet  
31  
Rev. 1.11, 2007-01  
07142005-CR47-RB2E  
 复制成功!