 浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第20页浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第21页浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第22页浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第23页浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第25页浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第26页浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第27页浏览型号HYB18TC512800BF-25F的Datasheet PDF文件第28页  
Internet Data Sheet  
HYB18TC512[80/16]0BF  
512-Mbit Double-Data-Rate-Two SDRAM  
5.2  
DC Characteristics  
TABLE 24  
Recommended DC Operating Conditions (SSTL_18)  
Symbol  
Parameter  
Rating  
Min.  
Unit  
Note  
Typ.  
Max.  
1)  
VDD  
Supply Voltage  
1.7  
1.8  
1.9  
V
V
V
V
V
1)  
VDDDL  
VDDQ  
VREF  
VTT  
Supply Voltage for DLL  
Supply Voltage for Output  
Input Reference Voltage  
Termination Voltage  
1.7  
1.8  
1.9  
1)  
1.7  
1.8  
1.9  
2)3)  
4)  
0.49 × VDDQ  
0.5 × VDDQ  
VREF  
0.51 × VDDQ  
V
REF – 0.04  
VREF + 0.04  
1)  
VDDQ tracks with VDD, VDDDL tracks with VDD. AC parameters are measured with VDD, VDDQ and VDDDL tied together.  
2) The value of VREF may be selected by the user to provide optimum noise margin in the system. Typically the value of VREF is expected to  
be about 0.5 × VDDQ of the transmitting device and VREF is expected to track variations in VDDQ  
3) Peak to peak ac noise on VREF may not exceed ± 2% VREF (dc)  
.
4)  
VTT is not applied directly to the device. VTT is a system supply for signal termination resistors, is expected to be set equal to VREF, and  
must track variations in die dc level of VREF  
.
TABLE 25  
ODT DC Electrical Characteristics  
Parameter / Condition  
Symbol  
Min.  
Nom.  
Max.  
Unit  
Note  
1)  
Termination resistor impedance value for  
EMRS(1)[A6,A2] = [0,1]; 75 Ohm  
Rtt1(eff)  
60  
75  
90  
1)  
1)  
2)  
Termination resistor impedance value for  
EMRS(1)[A6,A2] =[1,0]; 150 Ohm  
Rtt2(eff)  
Rtt3(eff)  
delta VM  
120  
40  
150  
50  
180  
%
Termination resistor impedance value for  
EMRS(1)(A6,A2)=[1,1]; 50 Ohm  
60  
Deviation of VM with respect to VDDQ / 2  
–6.00  
+ 6.00  
1) Measurement Definition for Rtt(eff): Apply VIH(ac) and VIL(ac) to test pin separately, then measure current I(VIHac) and I(VILac) respectively.  
Rtt(eff) = (VIH(ac) – VIL(ac)) /(I(VIHac) – I(VILac)).  
2) Measurement Definition for VM: Turn ODT on and measure voltage (VM) at test pin (midpoint) with no load: delta VM = ((2 x VM / VDDQ) –  
1) x 100%  
TABLE 26  
Input and Output Leakage Currents  
Symbol  
Parameter / Condition  
Min.  
Max.  
Unit  
Note  
1)  
IIL  
Input Leakage Current; any input 0 V < VIN < VDD  
Output Leakage Current; 0 V < VOUT < VDDQ  
–2  
–5  
+2  
+5  
µA  
µA  
2)  
IOL  
1) All other pins not under test = 0 V  
2) DQ’s, LDQS, LDQS, UDQS, UDQS, DQS, DQS, RDQS, RDQS are disabled and ODT is turned off  