LinkSwitch-HP
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
(Unless Otherwise Specified)
Parameter
Symbol
Min
Typ
Max
Units
Circuit Protection (cont.)
tLEB(MAX) + tILD(MAX)
Minimum Switch
ON-Time
TON(MIN)
325
400
500
ns
TJ = +25 °C
Output
TJ = +25 °C
6.9
10.5
4.6
7.0
3.5
5.4
2.3
3.6
1.8
2.7
1.5
2.3
1.3
2.0
7.97
12.08
5.30
8.09
4.03
6.21
2.65
4.14
2.07
3.11
1.95
2.90
1.70
2.60
470
LNK6xx3
ID = 100 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx4
ID = 150 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx5
ID = 200 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx6
ID = 300 mA
ON-State Resistance
RDS(ON)
W
TJ = +100 °C
TJ = +25 °C
LNK6xx7
ID = 400 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx8
ID = 500 mA
TJ = +100 °C
TJ = +25 °C
LNK6xx9
ID = 600 mA
TJ = +100 °C
VDS = 560 V, TJ = 125 °C
OFF-State Drain
Leakage Current
VPD
=
IDSS
mA
Floating
VDS = 325 V, TJ = 100 °C
10
LNK677x, VPD = Floating,
725
TJ = +25 °C
Breakdown Voltage
BVDSS
V
LNK666x/LNK676x, VPD = Floating,
TJ = +25 °C
650
50
DRAIN Supply Voltage
Rise Time
V
tR
100
50
Measured in a typical flyback
Converter application
ns
Fall Time
TF
NOTES:
A. Parameter not tested over specified temperature range. Guaranteed by design and characterization.
B. Average device switching frequency below 1 kHz.
16
Rev. E 06/15
www.power.com