TISPPBL2SD  
PROGRAMMABLE OVERVOLTAGE PROTECTORS  
FOR ERICSSON COMPONENTS PBL 3xxx SLICS  
AUGUST 1999  
Figure 9 and Figure 11 show these two waveform parameters in terms of device population. In Figure 9, the  
limiting voltage is shown in terms of the overshoot beyond the gate reference supply (VGG - V(BO)). Removing  
the gate reference voltage level magnifies the thyristor limiting voltage variation and shows the data  
stratification caused by the oscilloscope digitisation. Extrapolating the data trend indicates that the overshoot  
is less than 14 V at the 99.997% level (equal to 30 ppm of the population exceeding 14 V, equivalent to +4  
sigma point of a normal distribution). In Figure 11, extrapolating the thyristor data trend to the 99.997% level  
indicates a maximum breakdown time, t(BR), of 0.5 µs. Figure 12 shows that increasing the temperature up to  
85°C increases the thyristor peak limiting voltage by 2.4%, giving a maximum 85°C peak limiting voltage of  
1.024x(-50-14) = -65.5. Over the -40°C to 85°C temperature range the TISPPBL2S is specified to have a  
maximum V(BO) value of -70 V and a breakdown time, t(BR), of 1 µs.  
Figure 8 shows the total waveform variation of the diode limiting voltage across the 50 devices. The peak  
limiting voltage (Peak Forward Recovery Voltage VFRM) is less than 6 V, and this value includes the 2 V of  
magnetically induced noise in the probe. Figure 9 shows that extrapolated 99.997% level is about 5.5 V. In  
Figure 11, extrapolating the diode data trend to the 99.997% level indicates a maximum forward recovery  
time, tFR, of 0.1 µs. Figure 12 indicates that there is about a 10% uplift by increasing the temperature to 85°C.  
This gives a maximum 85°C peak limiting voltage of 1.1x(5.5) = 6.1 V. Over the -40°C to 85°C temperature  
range, the TISPPBL2S is specified to have a maximum VFRM value of 8 V and a maximum forward recovery  
time of 1 µs.  
Diodes do not switch to a much lower voltage like thyristors, so the diode limiting voltage applies for the whole  
impulse duration. Forward voltages of 1 V or less are normally considered safe. Figure 10 shows that the  
lowest current 1 V condition occurs at -40°C with a current of 0.3 A. When the TISPPBL2S is tested with the  
rated 10/1000 impulse it would take about 8 ms for the current to decay from 30 A to 0.3 A. Over the -40°C to  
85°C temperature range, the TISPPBL2S is specified to have a VF below 1 V within 10 ms.  
SLIC protection requirements  
This clause discusses the various requirements of the Ericsson Components SLICs detailed on the first page  
of this data sheet and compares these to the TISPPBL2S protector parameters. Some SLICs are rated for  
0°C to 70°C operation, others for -40°C to 85°C operation. The TISPPBL2S protector is specified for -40°C to  
85°C operation and so covers both temperature ranges.  
normal operation  
Depending on the SLIC type, the maximum SLIC supply voltage rating (VBat) will be -70 V, -80 V or -85 V. The  
-85V rating of the TISPPBL2S gate-cathode (VGKRM) matches the highest SLIC voltage rating.  
To restore normal operation after the TISPPBL2S has switched on, the minimum switch-off current (holding  
current IH) needed is equal to the maximum SLIC short circuit current to ground (d.c. line current together  
with the maximum longitudinal current). For the SLICs listed on the first page of this data sheet, the  
TISPPBL2S minimum holding current of 140 mA will ensure switch-off after an overvoltage.  
overvoltage protection  
Ericsson Components specify SLIC withstand capability as a series of stress-time values. Figure 15 shows  
the voltage withstand limits of the PBL 3762A SLIC.  
In the positive polarity, the PBL 3762A RING or TIP voltage must not exceed +15 V. For 250 ns, the PBL  
3762A will be able to withstand a voltage between +10 V and +15 V. For 1 µs, the PBL 3796 will be able to  
withstand a voltage between +5 V and +10 V. For 10 ms, the PBL 3796 will be able to withstand a voltage  
between +2 V and +5 V. To protect against positive overvoltage, the TISPPBL2S positive limiting voltage must  
be equal to or less than these voltage values during the specified time periods.  
P R O D U C T  
I N F O R M A T I O N  
10  