1.12.2 AIB Link Tests
All of the ETT1 devices use the high-speed AIB links for inter-device communication. The AIBs are used
exclusively for inter-device links between PCBs. The AIB links associated with a subsystem can be tested
while the subsystem is offline.
The following actions describe the procedure that should be used to test an AIB link attached to an offline
subsystem (one end of the link may be attached to an online subsystem).
1. If the other end of the AIB is attached to an online (active) subsystem then ensure that the AIB is
ignored by that subsystem, as follows:
•
•
•
•
Dataslice: this (test) AIB should be the secondary link.
EPP: this (test) AIB should be the secondary link.
Scheduler: disable the port associated with this (test) AIB. (Use the Enable Port register).
Xbar: no action needed.
2. Assert the reset control to both ends of the test AIB.
3. Enable the transmitters at both ends of the AIB.
4. De-assert the reset control to both ends of the test AIB.
5. The link should now come up -- the Ready bits associated with the link should be ‘1’. Interrupts will
also be generated if the mask bits are set appropriately.
6. Disable the transmitter at one end of the AIB.
7. The far end of the AIB should indicate CRC errors and that the link is not ready. (A few CRC errors
are generated before the link is considered down.)
8. Repeat steps 2 - 6 as needed to ensure that the link is OK. Also, leave the link up for a soak test
and ensure that no CRC errors are received.
1.12.3 Linecard to ETT1 Link Diagnostics
When a new portcard in installed in the ETT1 Fabric it will be necessary to ensure that the portcard is
operating correctly before bring it online. This section describes a number of tests that can be performed to
verify the linecard-to-ETT1 side of the card.
Figure 50 shows an example architecture of the portcard and its connection to the linecard on the left and
the ETT1 CPU on the right. The Dataslice is shown with two sets of queues.