欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM8621 参数 Datasheet PDF下载

PM8621图片预览
型号: PM8621
PDF下载: 下载PDF文件 查看货源
内容描述: NSE- 8G⑩标准产品数据表初步 [NSE-8G⑩ Standard Product Data Sheet Preliminary]
分类和应用:
文件页数/大小: 184 页 / 957 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM8621的Datasheet PDF文件第49页浏览型号PM8621的Datasheet PDF文件第50页浏览型号PM8621的Datasheet PDF文件第51页浏览型号PM8621的Datasheet PDF文件第52页浏览型号PM8621的Datasheet PDF文件第54页浏览型号PM8621的Datasheet PDF文件第55页浏览型号PM8621的Datasheet PDF文件第56页浏览型号PM8621的Datasheet PDF文件第57页  
NSE-8G™ Standard Product Data Sheet  
Preliminary  
9.9.1  
In-Band Signaling Channel Fixed Overhead  
The In-Band Link Controller block generates and terminates two bytes of fixed header and a  
CRC-16 per every 32 byte in-band message (total 36 bytes). The two byte header provides control  
and status between devices at the ends of the LVDS link. The CRC-16 is calculated over the 32  
byte (and header - 34 bytes) in-band message and provides the terminating end the ability to  
detect errors in the in-band message. The format of the in-band message and header bytes is  
shown in Figure 11 and Figure 12.  
Figure 11 In-Band Signaling Channel Message Format  
1 byte  
Header1  
1 byte  
Header2  
32 bytes  
Free Format Information  
2 bytes  
CRC-16  
Figure 12 In-Band Signaling Channel Header Format  
Header1  
Bit 7  
Bit 6  
Bit 5  
Bit4  
Bit3  
Bit2  
USER[2:0]  
Bit1  
Bit1  
Bit 0  
VALID  
LINK[1:0]  
PAGE[1:0]  
Header2  
Bit 7  
Bit 6  
Bit 5  
Bit4  
Bit3  
Bit2  
Bit 0  
AUX[7:0]  
Table 5 In-band Message Header Fields  
Field Name  
Valid  
NSE-8G to SBS  
SBS to NSE  
Message slot contains a message(1)  
or is empty(0). If empty this message  
will not be put into Rx Message FIFO  
(other header information processed  
as usual)  
Message slot contains a message(1)  
or is empty(0). If empty this message  
will not be put into Rx Message FIFO  
(other header information processed  
as usual)  
Link[1:0]#  
These bits are optional for SBI336S  
devices, intended for devices which  
have multiple redundant links. Each  
bit either indicates which Link to use,  
Working(0) or Protect(1) when  
These bits are optional for SBI336S  
devices, intended for devices which  
have multiple redundant links. Each  
bit either indicates which Link to use,  
Working(0) or Protect(1) when  
sourced from the master device, or  
which link is being used, when  
sourced from the master device, or  
which link is being used, when  
sourced from the slave device. Other  
algorithms are possible to indicate  
Working or Protect over these 2 bits  
but all SBI336S devices must be able  
to revert back to this meaning.  
sourced from the slave device. Other  
algorithms are possible to indicate  
Working or Protect over these 2 bits  
but all SBI336S devices must be able  
to revert back to this  
meaning.Transmitted immediately.  
Transmitted immediately.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-2010850, Issue 1  
52