NSE-8G™ Standard Product Data Sheet  
Preliminary  
Boundary Scan Instructions  
The following is a description of the standard instructions. Each instruction selects a serial test  
data register path between input, TDI and output, TDO.  
12.14.3 Instructions  
BYPASS  
The bypass instruction shifts data from input, TDI to output, TDO with one TCK clock period  
delay. The instruction is used to bypass the device.  
EXTEST  
The external test instruction allows testing of the interconnection to other devices. When the  
current instruction is the EXTEST instruction, the boundary scan register is place between input,  
TDI and output, TDO. Primary device inputs can be sampled by loading the boundary scan  
register using the Capture-DR state. The sampled values can then be viewed by shifting the  
boundary scan register using the Shift-DR state. Primary device outputs can be controlled by  
loading patterns shifted in through input TDI into the boundary scan register using the  
Update-DR state.  
SAMPLE  
The sample instruction samples all the device inputs and outputs. For this instruction, the  
boundary scan register is placed between TDI and TDO. Primary device inputs and outputs can  
be sampled by loading the boundary scan register using the Capture-DR state. The sampled  
values can then be viewed by shifting the boundary scan register using the Shift-DR state.  
IDCODE  
The identification instruction is used to connect the identification register between TDI and TDO.  
The device's identification code can then be shifted out using the Shift-DR state.  
STCTEST  
The single transport chain instruction is used to test out the TAP controller and the boundary scan  
register during production test. When this instruction is the current instruction, the boundary scan  
register is connected between TDI and TDO. During the Capture-DR state, the device  
identification code is loaded into the boundary scan register. The code can then be shifted out  
output, TDO using the Shift-DR state.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-2010850, Issue 1  
166  