RELEASED
PM7383 FREEDM-32A256
DATASHEET
PMC-2010336
ISSUE 1
FRAME ENGINE AND DATA LINK MANAGER 32A256
BUSY:
The indirect access status bit (BUSY) reports the progress of an indirect
access. BUSY is set high when this register is written to trigger an indirect
access, and will stay high until the access is complete. At which point, BUSY
will be set low. This register should be polled to determine when data from an
indirect read operation is available in the RHDL Indirect Channel Data #1 and
#2 registers or to determine when a new indirect write operation may
commence.
PROPRIETARY AND CONFIDENTIAL
104