RELEASED  
PM7350 S/UNI-DUPLEX  
DATA SHEET  
PMC-1980581  
ISSUE 5  
DUAL SERIAL LINK PHY MULTIPLEXER  
Register 0x70: Transmit Serial Indirect Channel Select  
Bit  
Type  
Function  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
R
R/W  
CBUSY  
CRWB  
X
0
X
X
0
0
0
0
Unused  
Unused  
CHAN[3]  
CHAN[2]  
CHAN[1]  
CHAN[0]  
R/W  
R/W  
R/W  
R/W  
This register provides the channel number used to access the channel provision  
RAM of the transmit Clocked Serial Data Interface. Writing to this register  
triggers an indirect channel register access.  
CHAN[3:0]:  
The indirect channel number bits (CHAN[3:0]) indicate the channel to be  
configured or interrogated in the indirect access.  
CRWB:  
The channel indirect access control bit (CRWB) selects between a configure  
(write) or interrogate (read) access to the channel provision RAM. Writing a  
logic zero to CRWB triggers an indirect write operation. Data to be written is  
taken from the Transmit Serial Indirect Channel Data registers. Writing a  
logic one to CRWB triggers an indirect read operation. The read can be  
found in the Transmit Serial Indirect Channel Data registers.  
CBUSY:  
The indirect access status bit (CBUSY) reports the progress of an indirect  
access. CBUSY is set to logic 1 when a write to the Transmit Serial Indirect  
Channel Select register triggers an indirect access and will stay high until the  
access is complete. This register should be polled to determine when data  
from an indirect read operation is available in the Transmit Serial Indirect  
Channel Data registers or to determine when a new indirect write operation  
may commence.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
166  