S/UNI-IMA-4 Telecom Standard Product Data Sheet  
Released  
Figure 13 Stuff Event with Errored ICP (Advanced Indication)  
Time  
M-1 Filler or  
ATM Layer Cells  
Stuff event  
ICP Cell  
ICP Cell  
IFSN # i+3  
LSI = 000  
ICP Cell  
IFSN # i+4  
LSI = 111  
ICP Cell  
IFSN # i+2  
LSI = 001  
ICP Cell  
Errored  
ICP Cell  
IFSN # i  
IFSN # i+3  
LSI = 000  
LSI = 011  
stuff_cnt =7  
stuff_cnt =0  
stuff_cnt =1  
stuff_cnt =2  
stuff_cnt =3  
IFSN: IMA Frame Sequence Number  
LSI: Link Stuffing Indication  
Figure 14 Invalid Stuff Sequence (Advanced Indication)  
Time  
M-1 Filler or  
ATM Layer Cells  
Stuff event  
ICP Cell  
IFSN # i+3  
LSI = 000  
ICP Cell  
IFSN # i+3  
LSI = 000  
ICP Cell  
IFSN # i+4  
LSI = 111  
ICP Cell  
IFSN # i+2  
LSI = 001  
ICP Cell  
IFSN #i+1  
LSI=001  
ICP Cell  
IFSN # i  
LSI = 011  
stuff_cnt =7  
stuff_cnt =0  
stuff_cnt =1  
stuff_cnt =2  
stuff_cnt =3  
IFSN: IMA Frame Sequence Number  
LSI: Link Stuffing Indication  
IMA Frame Synchronization with Stuff Events  
The RDAT will maintain synchronization while receiving stuff events subjected to HEC or CRC  
errors, as shown in Figure 15. When one of the ICP cells comprising a stuff event is errored or  
invalid, the other will be used. If both are errored or invalid, then the internally maintained stuff  
count will be used to identify the stuff event (given that the advanced indicators were correct).  
All of the cases assume that the IFSM is in the IMA Sync state prior to the window shown, and  
that the current errored/invalid counts are zero. Cases (1) through (6) require that alpha or beta  
be programmed to a value greater than one for synchronization to be maintained. Case (7)  
requires that alpha or beta be programmed to a value greater than two for synchronization to be  
maintained. Case (7) also requires that advance link stuff indication be given prior to the  
window shown in order to detect the stuff event.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.  
Document No.: PMC-2020889, Issue 2  
60  