欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7348 参数 Datasheet PDF下载

PM7348图片预览
型号: PM7348
PDF下载: 下载PDF文件 查看货源
内容描述: [ATM/SONET/SDH IC, CMOS, PBGA324,]
分类和应用: ATM异步传输模式
文件页数/大小: 318 页 / 1736 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7348的Datasheet PDF文件第150页浏览型号PM7348的Datasheet PDF文件第151页浏览型号PM7348的Datasheet PDF文件第152页浏览型号PM7348的Datasheet PDF文件第153页浏览型号PM7348的Datasheet PDF文件第155页浏览型号PM7348的Datasheet PDF文件第156页浏览型号PM7348的Datasheet PDF文件第157页浏览型号PM7348的Datasheet PDF文件第158页  
S/UNI-IMA-4 Telecom Standard Product Data Sheet  
Released  
WORD  
BIT  
DATA FIELD  
DESCRIPTION  
20  
Group_ICP_FWD_Filter  
Group ICP cell forwarding filtering enable.  
‘0’: No filtering. All ICP cells from RDAT will be  
forwarded to PM.  
‘1’: Filtering. RIPP will filter out the ICP cells  
that carry no new information (determined by  
the SCCI field) before forwarding to PM. In  
this mode, the RIPP will forward a minimum of  
1 cell per frame for the group in the absence of  
SCCI changes.  
19  
IMA_10_ENABLE  
RESERVED  
IMA version 1.0 style link state reporting  
enable. This field selects how the link state  
field in the incoming and outgoing ICP cells  
should be interpreted. Note that this bit will be  
ignored if the group is in asymmetric  
configuration mode.  
‘0’: IMA version 1.1 style (default)  
‘1’ IMA version 1.0 style.  
18:10  
9
PM_ADJUST_DELAY_DO  
NE_INT_EN  
PM adjust delay procedure done Interrupt  
enable. When disabled, this event cannot  
cause an entry to be written to the RIPP  
Interrupt FIFO for this group (although the  
status returned by read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
8
7
6
FE_TRL_INT_EN  
Invalid RX TRL Interrupt enable. When  
disabled, this event cannot cause an entry to  
be written to the RIPP Interrupt FIFO for this  
group (although the status returned by  
read_event may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
Group timing interrupt enable. When disabled,  
this event cannot cause an entry to be written  
to the RIPP Interrupt FIFO for this group  
(although the status returned by read_event  
may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
GROUP_TIMING_INT_EN  
FE_TIMEOUT_INT_EN  
FE Timeout Interrupt Enable. When disabled,  
this event cannot cause an entry to be written  
to the RIPP Interrupt FIFO for this group  
(although the status returned by read_event  
may be set).  
‘0’ Interrupt not enabled  
‘1’ Interrupt enabled.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.  
Document No.: PMC-2020889, Issue 2  
154  
 复制成功!