622 Mbps ATM Traffic Management Device  
7. 2. 34. RX_LOWER48_SCG_CONFIG  
Address: 1F0018h (7C0060h)  
Read/Write  
Function: Congestion configuration register for lower 48 (SC 8-31 and SC 40-63) Service Class  
Group  
Reset Value:0  
Format:  
Field (Bits)  
Description  
Not used  
(31:16)  
Write with a 0 to maintain future software compatibility.  
RX_LWR48_EXP_MAX_QD  
(15:12)  
Maximum QD (exponent or alternate) for service class group 8-31 and 40-63. This  
limit is enforced if RX_SCG_ENABLE=1.  
RX_LWR48_EXP_CONG_QD  
(11:8)  
Congestion QD (exponent or alternate) for service class group 8-31 and 40-63. This  
limit is enforced if RX_SCG_ENABLE=1.  
Not used  
(7:0)  
Write with a 0 to maintain future software compatibility.  
7. 2. 35. RX_LOWER48_SCG_STATE (Internal State)  
Address: 1F0019h (7C0064h)  
Read/Write  
Function: Queue state for lower 48 (SC 8-31 and SC 40-63) Service Class Group  
Reset Value:0  
Format:  
Field (Bits)  
Description  
Not used  
(31:20)  
Write with a 0 to maintain future software compatibility.  
RX_LWR48_MAXED  
(19)  
This SCG is currently in max congestion. Resets to 0. READ-ONLY.  
RX_LWR48_DECR_CONG  
(18)  
This queue depth for this service class group is currently larger than the queue depth  
defined by one codepoint less than RX_LWR48_CONG_QD. Resets to 0. READ-  
ONLY.  
RX_LWR48_DEF_CONG  
(17)  
This queue depth for this service class group is currently larger than the queue depth  
defined by RX_LWR48_CONG_QD. Resets to 0. READ-ONLY.  
RX_LWR48_CONGESTED  
(16)  
This service class group is currently in congestion as defined by  
RX_LWR48_CONG_QD, RX_HYSTERESIS_DISABLE, and  
RX_ALTERNATE_ENCODE. Resets to 0. READ-ONLY.  
RESERVED  
(15)  
Write with 0 each time SW_RESET is asserted to maintain future SW compatibility.  
RX_LWR48_DATA  
(14:0)  
Current queue depth for this SCG. Initialize to 0000 each time SW_RESET is  
asserted to maintain software compaitibility. Resets to 0000.  