7.2.26 RX_SENT_CELLS
Address: 1F0010h (7C0040h byte)
Type: Read-only
Function: Counts the number of cells accepted by the receive direction.
Reset Value:0
Format: Refer to the following table.
Field (Bits)
Description
Not used
(31:24)
Write with a 1 to maintain future software compatibility.
RX_SENT_CELLS
(23:0)
24-bit rollover counter of the number of cells accepted by the receive direction. This
counter is reset to 0 when SW_RESET = 1 or HW_RESET = 1 (refer to “SW_RESET”
and “HW_RESET” on page 101).
7.2.27 RX_DROPPED_CELLS
Address: 1F0011h (7C0044h byte)
Type: Read-only
Function: Counts the number of cells dropped by the receive direction.
Reset Value: 0
Format: Refer to the following table.
Field (Bits)
Description
Not used
(31:24)
Write with a 1 to maintain future software compatibility.
RX_DROPPED_CELLS
(23:0)
24-bit rollover counter of the number of cells dropped by the receive direction. This
counter is reset to 0 when SW_RESET = 1 or HW_RESET = 1 (refer to “SW_RESET”
and “HW_RESET” on page 101).
7.2.28 TX_SENT_CELLS
Address: 1F0012h (7C0048h byte)
Type: Read-only
Function: Counts the number of cells accepted (queued) by the transmit direction.
Reset Value: 0
Format: Refer to the following table.
Field (Bits)
Description
Not used
(31:24)
Write with a 1 to maintain future software compatibility.
TX_SENT_CELLS
(23:0)
24-bit rollover counter of the number of cells accepted by the transmit direction. This
counter is reset to 0 when SW_RESET = 1 or HW_RESET = 1 (refer to “SW_RESET”
and “HW_RESET” on page 101).