(Continued)  
Field (Bits)  
Description  
BP_IGNORED_FAIL_LATCH  
(15)  
1
0
Backpressure was ignored at least once since this latch was read.  
Backpressure was not ignored since this latch was read.  
Refer to section 3 “Fault Tolerance” starting on page 44 for more information.  
SE_INPUT_PORT_FAIL_LATCH  
(14:11)  
Bit 14 corresponds to port 3, bit 13 corresponds to port 2, bit 12 corresponds to port  
1 and bit 11 corresponds to port 0 as follows:  
1
One of the following was detected at least once since this latch was  
read:  
Bad SOC pattern  
invalid cell code  
bad idle cell code  
fabric out of synch  
0
None of the above has been detected since this latch was read.  
Refer to section 3 “Fault Tolerance” starting on page 44 for more information.  
BP_REMOTE_FAIL_LATCH  
(10:7)  
Bit 10 corresponds to port 3, bit 9 corresponds to port 2, bit 8 corresponds to port 1  
and bit 7 corresponds to port 0 as follows:  
1
0
The forward data path was bad at least once since this latch was read.  
The forward data path was not bad at least once since this latch was  
read.  
Refer to section 3 “Fault Tolerance” starting on page 44 for more information.  
BP_ACK_FAIL_LATCH  
(6:3)  
Bit 6 corresponds to port 3, bit 5 corresponds to port 2, bit 4 corresponds to port 1  
and bit 3 corresponds to port 0 as follows:  
1
The BP_ACK_IN(3:0) line did not have the required pattern at least  
once since this latch was read.  
0
The BP_ACK_IN(3:0) line did have the required pattern at least once  
since this latch was read.  
OUT_WD_INT_LATCH  
(2)  
1
0
At least one of the UTOPIA output watchdogs expired since the last  
time this register was read.  
None of the UTOPIA output watchdogs expired since the last time this  
register was read.  
EQD_INT_LATCH  
(1)  
1
0
The empty queue depth threshold was crossed in either direction since  
this latch was read.  
The empty queue depth threshold was not crossed in either direction  
since this latch was read. The congestion is declared to have been  
relieved when the queue depth crossed back above twice the configured  
congestion threshold.  
Reserved  
(0)  
Initialize to 0 at initial setup. Software modifications to these locations after setup  
may cause incorrect operation.  