S/UNI®-JET Data Sheet
Released
13 Operation
13.1 Software Initialization Sequence
Using the following software initialization sequence puts the S/UNI-JET in a normal power
consumption state. PMC-Sierra™ strongly recommends using this reset sequence to guarantee the
device’s long term reliability.
Note: After a reset, the S/UNI-JET may start using more power than is required. While the
device’s normal operations are not altered, the excessive power consumption can cause the device
to give off high levels of heat, which in turn, could lead to future problems with the device.
To initialize the device:
•
•
Reset the S/UNI-JET.
Set IOTST (bit 2) in the Master Test Register (datasheet pg. 291) to '1' (by writing 00000100
to register 400H).
•
•
Put the S/UNI-JET Receive Cell Processor (RXCP) into test mode by writing:
°
°
°
°
00000101 to test register 461H
00000101 to test register 561H
00000101 to test register 661H
00000101 to test register 761H
Set the S/UNI-JET Receive Cell Processor block built in set test (BIST) controls signals by
writing:
°
°
°
°
°
°
°
°
01000000 to test register 462H
01000000 to test register 562H
01000000 to test register 662H
01000000 to test register 762H
10101010 to test register 463H
10101010 to test register 563H
10101010 to test register 663H
10101010 to test register 763H
•
Put the S/UNI-JET Transmit Cell Processor (TXCP) into test mode by writing:
°
°
°
°
00000011 to test register 481H
00000011 to test register 581H
00000011 to test register 681H
00000011 to test register 781H
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990267, Issue 3
259