PM7344 S/UNI-MPH  
DATA SHEET  
PMC-950449  
ISSUE 6  
MULTI-PHY USER NETWORK INTERFACE  
Registers 01DH, 11DH, 21DH and 31DH: T1-FRMR Interrupt Enable  
Bit  
Type  
Function  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Unused  
Reserved  
COFAE  
FERE  
BEEE  
SFEE  
X
0
0
0
0
0
0
0
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
MFPE  
INFRE  
These registers select which of the MFP, COFA, FER, BEE, SFE, or INFR events  
generates an interrupt on the microprocessor INTB pin when their state changes  
or their event condition is detected.  
Reserved:  
The reserved bit must be programmed to logic 0 for correct operation.  
COFAE:  
The COFAE bit enables the generation of an interrupt when the frame find  
circuitry determines that frame alignment has been achieved and that the  
new alignment differs from the previous alignment. When COFAE is set to  
logic 1, the declaration of a change of frame alignment is allowed to generate  
an interrupt. When COFAE is set to logic 0, a change in the frame alignment  
does not generate an interrupt.  
FERE:  
The FERE bit enables the generation of an interrupt when a framing bit error  
has been detected. When FERE is set to logic 1, the detection of a framing  
bit error is allowed to generate an interrupt. When FERE is set to logic 0, any  
error in the framing bits does not generate an interrupt.  
BEEE:  
The BEEE bit enables the generation of an interrupt when a bit error event  
has been detected. A bit error event is defined as framing bit errors for SF  
formatted data, and CRC-6 errors for ESF formatted data. When BEEE is set  
to logic 1, the detection of a bit error event is allowed to generate an interrupt.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  