PM7340 S/UNI-IMA-8
PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
11.7 RIPP Registers
Register 0x200:RIPP Control
Bit
Type
Function
Default
15
14
13
12: 0
R/W
R/W
R
RIPP_EN
Reserved
RIPP_BUSY
Reserved
0
0
0
0
RIPP_BUSY
This is a status signal indicating that the RIPP main-state machine is currently
active. This bit is generated by RIPP.
RIPP_EN
The RIPP_EN enables the RIPP main state machine for normal operations.
When RIPP_EN = 0 and RIPP_BUSY = 0, all RIPP operations are disabled.
The RIPP_EN should be set to a ‘1’ for normal operations after the
initialization of RIPP context memory.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE