PM7340 S/UNI-IMA-8
PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
0) No cell transfer error occurred on the TX ANY-PHY/UTOPIA interface.
1) A cell transfer error occurred on the TX ANY-PHY/UTOPIA interface.
SDRAM_CRC_ERR
When set, it indicates that a SDRAM CRC Error occurred when a cell buffer
was read from SDRAM. This bit is cleared on read.
0) No SDRAM CRC error occurred.
1) SDRAM CRC error occurred.
TC_INTR_FOVR_ERR
When set, it indicates that the TC Interrupt FIFO overflowed and status
reporting information was lost. To determine the status of the physical Links,
the physical-link status for each link must be polled. This bit is cleared on
read.
0) The TC Interrupt FIFO has not overflowed.
1) The TC Interrupt FIOF has overflowed.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
105