欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7325-TC 参数 Datasheet PDF下载

PM7325-TC图片预览
型号: PM7325-TC
PDF下载: 下载PDF文件 查看货源
内容描述: S / UNI - ATLAS -3200电信标准产品数据表初步 [S/UNI-ATLAS-3200 Telecom Standard Product Data Sheet Preliminary]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信电路异步传输模式
文件页数/大小: 432 页 / 2222 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7325-TC的Datasheet PDF文件第93页浏览型号PM7325-TC的Datasheet PDF文件第94页浏览型号PM7325-TC的Datasheet PDF文件第95页浏览型号PM7325-TC的Datasheet PDF文件第96页浏览型号PM7325-TC的Datasheet PDF文件第98页浏览型号PM7325-TC的Datasheet PDF文件第99页浏览型号PM7325-TC的Datasheet PDF文件第100页浏览型号PM7325-TC的Datasheet PDF文件第101页  
S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Table 20 Actions on Policing with COCUP=1  
GCRA1  
GCRA2  
Pass  
Fail  
No Action  
Update TAT1  
Tag  
Discard  
Pass  
Fail  
Update TAT1  
Update TAT2  
Update TAT2  
Update TAT2  
No Update  
Update TAT1  
No Update  
No Action  
Tag  
Discard  
No Update  
No Update  
No Update  
No Update  
No Update  
No Update  
No Update  
No Update  
No Update  
In both cases (COCUP=1 and COCUP=0), if a cell fails both GCRA1 and GCRA2, the most  
severe action is taken on the cell.  
The three 16-bit non-compliant counts are programmed in either the NCOUNTx[3:0] or the  
GFR_NCOUNTx[3:0] fields of the Per-VC Non-Compliant Cell Counting Configuration,  
depending on whether the GFR bit is set to logic 1 in the policing configuration field of the VC  
table. Each non-compliant count has the following programming options:  
Table 21 Non-Compliant Cell Count Configurations  
NCOUNTx[3:0]  
0000  
Definition  
Non-compliant CLP=0 cells.  
0001  
Non-compliant CLP=0+1 cells.  
0010  
Discarded CLP=0 cells.  
0011  
Discarded CLP=0+1 cells.  
0100  
0101  
0110  
0111  
1000  
1001  
1010  
1011  
1100  
1101  
1110  
1111  
Tagged CLP=0 cells which are not discarded  
Non-compliant CLP=0 frames (GFR only)  
Non-compliant CLP=0+1 frames (GFR only)  
Partially or Completely Discarded CLP=0 frames (GFR Only)  
Partially or Completely Discarded CLP=0+1 frames (GFR Only)  
Tagged CLP=0 Frames which are not discarded (GFR Only)  
Total CLP=0 AAL5 Frames Received  
Total CLP=0+1 AAL5 Frames Received  
Total cells non-compliant to GCRA1  
Total cells non-compliant to GCRA2  
Total cells non-compliant to the PHY GCRA  
Reserved  
The Total AAL5 Frames Received counts are available in non-GFR connections, but the other  
frame-aware counts should not be selected except in the GFR case. Counting of CLP0 vs. CLP 1  
frames is based on the CLP of the received EOP.  
These non-compliant cell counts may, for instance, be programmed to satisfy the following  
requirements:  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
97  