PMC-Sierra, Inc.
PRELIMINARY
PM5381 S/UNI-2488
DATASHEET
PMC-2000489
ISSUE 1
SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S
Indirect Register 0804H: PRGM Monitor Error Count Page
Bit
Type
Function
Default
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
ERR_CNT[15]
ERR_CNT[14]
ERR_CNT[13]
ERR_CNT[12]
ERR_CNT[11]
ERR_CNT[10]
ERR_CNT[9]
ERR_CNT[8]
ERR_CNT[7]
ERR_CNT[6]
ERR_CNT[5]
ERR_CNT[4]
ERR_CNT[3]
ERR_CNT[2]
ERR_CNT[1]
ERR_CNT[0]
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
ERR_CNT[15:0]:
The ERR_CNT[15:0] register is the number of error in the PRBS bytes detected during the
monitoring. Errors are accumulated only when the monitor is in the synchonized state. Even
if there are multiple errors within one PRBS byte, only one error is counted. The transfer of
the error counter to this holding register is trigger by an indirect write to this register or writing
register 0000H for a global performance monitor update. The error counter will not wrap
around after reaching FFFFH. It will saturate to this value.
Proprietary and Confidentail to PMC-Sierra Inc., and for its Customer’s Internal Use
399