PMC-Sierra, Inc.
PRELIMINARY
PM5381 S/UNI-2488
DATASHEET
PMC-2000489
ISSUE 1
SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S
Register 0208H, 0210H, 0218H, 0220H, 0228H, 0230H, 0238H, 0240H, 0248H, 0250H, 0258H, 0260H
Register 0288H, 0290H, 0298H, 02A0H, 02A8H, 02B0H, 02B8H, 02C0H, 02C8H, 02D0H, 02D8H, 02E0H
Register 0308H, 0310H, 0318H, 0320H, 0328H, 0330H, 0338H, 0340H, 0348H, 0350H, 0358H, 0360H
Register 0388H, 0390H, 0398H, 03A0H, 03A8H, 03B0H, 03B8H, 03C0H, 03C8H, 03D0H, 03D8H, 03E0H:
RHPP STS-1/STM-0 #N (where N=1 to 48) Pointer Interpreter Status
Bit
Type
Function
Default
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Unused
PAISCV
PLOPCV
PAISV
Bit 8
Bit 7
Bit 6
Bit 5
R
R
R
R
X
X
X
X
Bit 4
Bit 3
Bit 2
PLOPV
Unused
Unused
Bit 1
Bit 0
PLOPV:
The path lost of pointer state (PLOPV) bit indicates the current status of the pointer
interpreter state machine. PLOPV is set to logic 1 when the state machine is in the
LOP_state. PLOPV is set to logic 0 when the state machine is not in the LOP_state.
This bit is only valid for RHPP STS-1/STM0 #1.
PAISV:
The path alarm indication signal state (PAISV) bit indicates the current status of the pointer
interpreter state machine. PAISV is set to logic 1 when the state machine is in the AIS_state.
PAISV is set to logic 0 when the state machine is not in the AIS_state.
This bit is only valid for RHPP STS-1/STM0 #1.
Proprietary and Confidentail to PMC-Sierra Inc., and for its Customer’s Internal Use
203