欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM5381 参数 Datasheet PDF下载

PM5381图片预览
型号: PM5381
PDF下载: 下载PDF文件 查看货源
内容描述: SATURN用户网络接口,用于2488 Mbit / s的 [SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S]
分类和应用: 网络接口
文件页数/大小: 487 页 / 2424 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM5381的Datasheet PDF文件第218页浏览型号PM5381的Datasheet PDF文件第219页浏览型号PM5381的Datasheet PDF文件第220页浏览型号PM5381的Datasheet PDF文件第221页浏览型号PM5381的Datasheet PDF文件第223页浏览型号PM5381的Datasheet PDF文件第224页浏览型号PM5381的Datasheet PDF文件第225页浏览型号PM5381的Datasheet PDF文件第226页  
PMC-Sierra, Inc.  
PRELIMINARY  
PM5381 S/UNI-2488  
DATASHEET  
PMC-2000489  
ISSUE 1  
SATURN USER NETWORK INTERFACE FOR 2488 MBIT/S  
1011  
1100  
Path #(11, 23, 35 or47)  
Path #(12, 24, 36 or 48)  
Invalid path  
1101-1111  
IADDR[2:0]:  
The address location (IADDR[2:0]) bits select which address location is accessed by the  
current indirect transfer.  
Indirect Address  
IADDR[2:0]  
Indirect Data  
000  
001  
010  
011  
100  
101  
Pointer Interpreter Configuration  
Error Monitor Configuration  
Pointer Value and ERDI  
Captured and Accepted PSL  
Expected PSL and PDI  
GPO and status  
101  
to  
Unused  
111  
RWB:  
The active high read and active low write (RWB) bit selects if the current access to a internal  
register is an indirect read or an indirect write. Writing to the Indirect Address Register  
initiates an access to a register. When RWB is set to logic 1, an indirect read access to a  
register is initiated. The data from the addressed location as indicated using the IADDR field  
will be transferred to the Indirect Data Register. When RWB is set to logic 0, an indirect write  
access to a register is initiated. The data from the Indirect Data Register will be transferred to  
the addressed register.  
BUSY:  
The active high busy (BUSY) bit reports if a previously initiated indirect access to an internal  
register has been completed. BUSY is set to logic 1 upon writing to the Indirect Address  
Register. BUSY is set to logic 0, upon completion of the access. This register should be  
polled to determine when new data is available in the Indirect Data Register.  
Proprietary and Confidentail to PMC-Sierra Inc., and for its Customer’s Internal Use  
201  