STANDARD PRODUCT
PM5365 TEMAP
DATASHEET
PMC-1991148
ISSUE 3
HIGH DENSITY VT/TU MAPPER
AND M13 MULTIPLEXER
Table 46: Ingress Interface Timing - Clock Master Modes (Figure 68)
Symbol
tP
Description
Min
Max
Units
ICLK[x] to Ingress Output Prop.
Delay9,10,11
-20
20
ns
ICLK
Figure 68: Ingress Interface Timing - Clock Master Modes
ICLK[x]
ID[x]
Valid
IFP[x]
tP
ICLK
Proprietary and Confidential to PMC-Sierra, Inc. and for its Customers’ Internal Use
225