STANDARD PRODUCT
PM5365 TEMAP
DATASHEET
PMC-1991148
ISSUE 3
HIGH DENSITY VT/TU MAPPER
AND M13 MULTIPLEXER
Notes on SBI Output Timing:
1. Output propagation delay time is the time in nanoseconds from the 1.4 Volt
point of the reference signal to the 1.4 Volt point of the output.
2. Maximum and minimum output propagation delays are measured with a 100
pF load on all the outputs.
3. Maximum and minimum output propagation delay is measured with a 50pF
load.
4. Output tristate delay is the time in nanoseconds from the 1.4 Volt point of the
reference signal to the point where the total current delivered through the
output is less than or equal to the leakage current.
5. When a set-up time is specified between an input and a clock, the set-up
time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4
Volt point of the clock.
6. When a hold time is specified between an input and a clock, the hold time is
the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt
point of the input.
Figure 63: SBI DROP BUS Timing
SREFCLK
tP
tP
BIDROP
BIACT
S
S
SDDATA[7:0]
SDDP, SDPL
SDV5
SBIACT
tZ
SBIDROP
SDDATA[7:0]
SDDP, SDPL
SDV5
Proprietary and Confidential to PMC-Sierra, Inc. and for its Customers’ Internal Use
220