欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM5363-BI 参数 Datasheet PDF下载

PM5363-BI图片预览
型号: PM5363-BI
PDF下载: 下载PDF文件 查看货源
内容描述: SONET / SDH支路单元荷载处理器, 622兆比特/ s接口 [SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S INTERFACES]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信集成电路电信电路异步传输模式
文件页数/大小: 459 页 / 3435 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM5363-BI的Datasheet PDF文件第22页浏览型号PM5363-BI的Datasheet PDF文件第23页浏览型号PM5363-BI的Datasheet PDF文件第24页浏览型号PM5363-BI的Datasheet PDF文件第25页浏览型号PM5363-BI的Datasheet PDF文件第27页浏览型号PM5363-BI的Datasheet PDF文件第28页浏览型号PM5363-BI的Datasheet PDF文件第29页浏览型号PM5363-BI的Datasheet PDF文件第30页  
PM5363 TUPP+622  
TUPP+622  
DATASHEET  
PMC-1981421  
ISSUE 4  
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S  
INTERFACES  
Detects tributary path signal label unstable alarms (PSLU) and return to stable  
state for each tributary and optionally generates interrupts.  
Detects tributary unequipped defect (UNEQ) and tributary path defect  
indication (PDI-V).  
Detects assertion and removal of tributary extended remote defect indications  
(RDI) for each tributary and optionally generates interrupts.  
Calculates and compares the tributary path BIP-2 error detection code for  
each tributary and configurable to accumulate the BIP-2 errors, on block or bit  
basis, in internal registers.  
Calculates and compares the TU3 path BIP-8 error detection code for each  
TU3 stream and accumulates the BIP-8 errors, on block or bit basis, in  
internal registers.  
Accumulates TU3 tributary remote error indications (REI) on a bit or a block  
basis, in internal registers.  
Allows insertion of all-zeros or all-ones tributary idle code with unequipped  
indication and valid pointer into any tributary under software control. Idle  
tributaries are identified by an output signal.  
Identifies outgoing tributaries that are in AIS state by an output signal. Allows  
software to force the AIS insertion on a per tributary basis.  
Inserts valid H4 byte and all-zeros fixed stuff bytes on the outgoing stream.  
Remaining path overhead bytes (J1, B3, C2, G1, F2, Z3, Z4, and Z5) can be  
configured to be set to all-zeros or to reflect the value of the corresponding  
POH bytes in the incoming stream.  
Inserts valid pointers (H1, H2), framing bytes (A1, A2), and all-zeros transport  
overhead bytes on the outgoing stream with valid "TeleCombus" control  
signals.  
Supports in-band error reporting by updating the REI, RDI and auxiliary RDI  
bits in the V5 byte (G1 in TU3) with the status of the incoming stream.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
3
 复制成功!