PM5362TUPP-PLUS
DATA SHEET
PMC-951010
ISSUE 6
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR
Register 12H:Tributary Auxiliary Remote Defect Indication Control
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
NOLOMARDI
NOLOPARDI
NOAISARDI
UNEQARDI
PSLMARDI
PSLUARDI
TIMARDI
1
1
1
0
0
0
0
0
TIUARDI
This register controls the insertion of tributary path auxiliary RDI on the receive
alarm port (RAD) and optionally on the V5 byte (G1 in TU3 mode) as a result of
tributary pointer alarms, tributary path signal label alarms, tributary trace
identifier alarms and tributary multiframe alarms.
TIUARDI:
The TIUARDI bit is an active high auxiliary RDI insertion enable. When
TIUARDI is set high, ARDI is reported on RAD and optionally in the V5 byte
(G1 byte in TU3 mode) of the outgoing data stream for all tributaries that are
in trace identifier unstable state. When TIURDI is set low, reporting of
auxiliary RDI due to TIM is inhibited.
TIMARDI:
The TIMARDI bit is an active high auxiliary RDI insertion enable. When
TIMARDI is set high, ARDI is reported on RAD and optionally in the V5 byte
(G1 byte in TU3 mode) of the outgoing data stream for all tributaries that are
in trace identifier mismatch state. When TIUARDI is set low, reporting of
auxiliary RDI due to TIM is inhibited.
PSLUARDI:
The PSLUARDI bit is an active high auxiliary RDI insertion enable. When
PSLUARDI is set high, ARDI is reported on RAD and optionally in the V5 byte
(G1 byte in TU3 mode) of the outgoing data stream for all tributaries that are
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
104