Register 003H: Receive Line Interface Configuration  
Bit  
Type  
Function  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
AUTOYELLOW  
AUTORED  
AUTOOOF  
AUTOAIS  
RUNI  
0
0
0
0
0
0
0
0
BPV  
RDATINV  
RFALL  
AUTOYELLOW:  
In T1 mode, when the AUTOYELLOW bit is set to logic 1, whenever the  
alarm integrator declares a Red alarm in the receive direction, Yellow alarm  
will be transmitted to the far end. When AUTOYELLOW is set to logic 0,  
Yellow alarm will only be transmitted when the XYEL bit is set in the T1-XBAS  
Alarm Transmit Register. Note that the Red alarm is not deasserted on  
detection of AIS.  
In E1 mode, when the AUTOYELLOW bit is set to logic 1, The RAI bit in the  
transmit stream is set to a logic 1 for the duration of a loss of frame alignment  
or AIS. The G706ANNBRAI bit of the Transmit Framing and Bypass Options  
register optionally also allows for the transmission of RAI when CRC-to-non-  
CRC interworking has been established. When AUTOYELLOW is set to  
logic 0, RAI will only be transmitted when the RAI bit is set in the E1-TRAN  
Transmit Alarm/Diagnostic Control register.  
AUTORED:  
The AUTORED bit allows global trunk conditioning to be applied to the  
receive data and signaling streams, BRPCM and BRSIG, immediately upon  
declaration of Red carrier failure alarm. When AUTORED is set to logic 1,  
the data on BRPCM for each channel is replaced with the data contained in  
the Data Trunk Conditioning registers within RPSC and the data on BRSIG  
for each channel is replaced with the data contained in the Signaling Trunk  
Conditioning registers within the RPSC while Red CFA is declared. When  
AUTORED is set to logic 0, the receive data is not automatically conditioned  
when Red CFA is declared.  
PROPRIETARY AND CONFIDENTIAL  
82  