5. Parameter tHAR is not applicable if address latching is used.
6. When a set-up time is specified between an input and a clock, the set-up
time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4
Volt point of the clock.
7. When a hold time is specified between an input and a clock, the hold time is
the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt
point of the clock.
Table 31: Microprocessor Interface Write Access
Symbol
Parameter
Min
Max
Units
tSAW
tSDW
tSALW
tHALW
tVL
tSLW
tHLW
tHDW
tHAW
TVWR
Address to Valid Write Set-up Time
Data to Valid Write Set-up Time
Address to Latch Set-up Time
Address to Latch Hold Time
Valid Latch Pulse Width
Latch to Write Set-up
Latch to Write Hold
Data to Valid Write Hold Time
Address to Valid Write Hold Time
Valid Write Pulse Width
10
20
10
10
20
0
5
5
5
40
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
PROPRIETARY AND CONFIDENTIAL