4.2.2 Heart Rate Detection Performance
Parameters
Heart Rate Measurement Range 30 - 240
Value
Unit
bpm
bpm
bpm
Conditions
±3
@ Room temperature for steady state: 0 km/hr.
@ Room temperature for motion state: 0 – 9 km/hr
on the treadmill.
Heart Rate Tolerance of Root
Mean Square (RMS)
±5
Response Time
8 - 10
second
@ Heart Rate = 72/bpm
Notes:
. PAH8002EP can provide heart rate measurement. However, it is not for medical device usage.
. For usage of heart rate detection chip on the wearable device that to be put on the wrist, finger or palm,
. The chip must be placed securely and in-contact with the skin surface as well as keeping it stable without any motion
during measurement in acquiring accurate heart rate measurement.
. Do not wear the device on the wrist bone. It should be wear on the higher position of, especially for those with a
smaller wrist.
. Chip’s performance is optimized with good blood flow. It is recommended to have light exercise for a few minutes to
increase your blood flow before turning on the heart rate monitor.
. On cold weather condition or user is having poor blood circulation (e.g.: cold hands, fingers and feet), the chip
performance (heart rate accuracy) could be effected as the blood flow is slower in the measuring spot position. It is
recommended to activate the heart rate monitor in indoor use.
. If the chip is having problem to read heart rate, may try to swap it on the other side of hand wrist to repeat the
measurement.
. For continuous heart rate measurement, do minimize hand movement and extreme bending of the wrist.