 浏览型号POE576U-8UP-N-R的Datasheet PDF文件第37页浏览型号POE576U-8UP-N-R的Datasheet PDF文件第38页浏览型号POE576U-8UP-N-R的Datasheet PDF文件第39页浏览型号POE576U-8UP-N-R的Datasheet PDF文件第40页浏览型号POE576U-8UP-N-R的Datasheet PDF文件第41页浏览型号POE576U-8UP-N-R的Datasheet PDF文件第42页浏览型号POE576U-8UP-N-R的Datasheet PDF文件第43页浏览型号POE576U-8UP-N-R的Datasheet PDF文件第45页  
6.  
Troubleshooting  
If problems occur with the midspan, check the following troubleshooting table:  
The troubleshooting solutions provided can only solve minor problems. If your problem is not listed,  
please contact our Phihong directly for further technical assistance. All up-to-date contact information  
can be found on our website www.phihong.com or www.midspans.com.  
Troubleshooting  
Problem  
Possible Solutions  
1. Ensure that the AC ppower cord is connected  
2. Ensure that the AC power cord is in good  
condition  
Midspan does not power up  
3. If solutions 1 and 2 are true; then disconnect  
the AC power cord and reconnect. Observe  
the Port LEDs to verify a proper power up.  
1. The Port may be disabled and needs to  
be enabled using either the web or SNMP  
interfaces. Ensure that the Port in question is  
Enabled  
Port LEDs do not illuminate “Green”  
2. Ensure the NIC Port is properly connected to  
the Network  
Use the default IP address 10.0.2.5 and connect  
the midspan to the PC directly. Refer to the  
section TFTP uploading (Power-On Reset Entry  
Mode) for more details. If 10.0.2.5 will not open  
the correct webpage, check the network for any  
possible faults.  
The web interface won’t open or cannot  
contact the unit via SNMP  
The web does not update the port status  
SNMP can’t make contact  
Execute System Tools » Reboot  
Check to see if the community strings are correct  
1. Make sure the power is applied to the midspan  
2. Make sure the network ethernet cable is not  
connected to the POE Data and Power port  
3. Make sure the Data and Power cable is not  
connected to the Ethernet (NIC) power  
For all other issues, please verify the following:  
4. Ensure the proper type of Ethernet cable is  
used. Do not use a crossover type of Ethernet  
cable.  
Phihong USA Corporation • 47800 Fremont Blvd. Fremont, CA 94538 • Tel: 1.510.445.0100 Fax: 1.510.445.1678  
www.phihong.com or www.midspans.com  
-44-  