“ZNR” Transient/Surge Absorbers (Type D)
■ Reference Guide to Standard Products
Maximum
Allowable
Voltage
Clamping
Voltage
@8/20µs
Maximum
Energy
(J)
Maximum
Peak Current
@8/20µs(A)
Varistor
Voltage✽
Part No.
Recommended Applications
(V)
ACrms (V) DC (V) max.(V) Ip (A) 10/1000 µs 2 ms 1 time 2 times
ERZV05D391
ERZV07D391
ERZV09D391
ERZV10D391
ERZV14D391
ERZV20D391
ERZV05D431
ERZV07D431
ERZV09D431
ERZV10D431
ERZV14D431
ERZV20D431
ERZV05D471
ERZV07D471
ERZV09D471
ERZV10D471
ERZV14D471
ERZV20D471
ERZV07D511
ERZV09D511
ERZV10D511
ERZV14D511
ERZV20D511
ERZV10D621
ERZV14D621
ERZV20D621
ERZV10D681
ERZV14D681
ERZV20D681
ERZV10D751
ERZV14D751
ERZV20D751
ERZV10D821
ERZV14D821
ERZV20D821
ERZV10D911
ERZV14D911
ERZV20D911
ERZV10D102
ERZV14D102
ERZV20D102
ERZV10D112
ERZV14D112
ERZV20D112
ERZV10D182CS
ERZV14D182CS
ERZV20D182
675
650
5
10
17
35
12
25
800
600
AC 100 V to 120 V, Line–Line
Applications
1750 1250
3500 2500
3500 2500
6000 4500
10000 6500
650
25
70
50
390
(351–429)
250
275
320
350
Telephone Line Applications,
(250 V Insulation Resistance
Test Applicable)
650
25
70
50
650
50
140
275
20
100
195
13.5
27.5
55
650
100
5
745
800
600
710
10
40
1750 1250
3500 2500
3500 2500
6000 4500
10000 6500
AC 100 V to 220 V, Line–Line
and
AC 100 V to 220 V,
Line–Ground Applications
710
25
80
430
(387–473)
710
25
80
55
710
50
155
303
21
110
215
15
710
100
5
810
800
600
775
10
42
30
1750 1250
3500 2500
3500 2500
6000 4500
10000 6500
1750 1250
3500 2500
3500 2500
6000 4500
10000 6500
3500 2500
5000 4500
7500 6500
3500 2500
5000 4500
7500 6500
3500 2500
5000 4500
7500 6500
3500 2500
5000 4500
7500 6500
3500 2500
AC 100 V to 220 V, Line–Line
and
AC 100 V to 220 V,
Line–Ground Applications
775
25
85
60
470
(423–517)
300
320
385
410
775
25
85
60
775
50
175
350
45
125
250
32
775
100
10
845
845
25
92
67
510
(459–561)
845
25
92
67
845
50
190
382
92
136
273
67
AC 100 to 240 V, Line–Line
Applications
AC 100 to 240 V, Line–Ground
Applications
845
100
25
1025
1025
1025
1120
1120
1120
1240
1240
1240
1355
1355
1355
1500
1500
1500
1650
1650
1650
1815
1815
1815
2970
2970
2970
620
(558–682)
385
420
460
510
505
560
615
50
190
382
92
136
273
67
100
25
680
(612–748)
50
190
382
100
210
420
110
235
460
130
255
510
140
280
565
155
310
620
247
510
1020
136
273
70
100
25
750
(675–825)
50
150
300
80
AC 380 V, Line–Line and
Line–Ground Applications
(For DC 500 V Insulating Test)
100
25
820
(738–902)
670
745
50
165
325
90
100
25
AC 415 V, Line–Line and
910
(819–1001)
550
625
680
1000
50
180
360
100
200
400
110
220
440
183
360
720
5000 4500 Line–Ground Applications
(For DC 500 V Insulating Test)
100
25
7500 6500
3500 2500
5000 4500
1000
(900–1100)
825
895
1465
50
AC 480 V, Line–Line and
Line–Ground Applications
(For DC 500 V Insulating Test)
100
25
7500 6500
3500 2500
1100
(990–1210)
50
5000 4500
7500 6500
100
25
3500 2500
Line–Ground Applications
1800
(1700–1980)
50
5000 4500 (For AC 1200 V Withstanding
Test)
100
7500 6500
✽
Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
00 Sep. 2010
– 303 –