KAI−04070
DC Bias Operating Conditions
Table 14. DC BIAS OPERATING CONDITIONS
Max. DC
Current
Description
Reset Drain
Pins
RDa
Symbol
RD
Min.
Nom.
12.6
−2.0
15.0
0.0
Max.
12.8
−1.8
15.5
0.0
Unit
V
Notes
1, 9
1
12.4
−2.2
14.5
0.0
10 mA
10 mA
11.0 mA
−1.0 mA
50 mA
50 mA
−
Output Gate
OGa
OG
V
Output Amplifier Supply
Ground
VDDa
GND
SUB
V
DD
V
1, 2
GND
V
Substrate
V
SUB
5.0
V
AB
V
DD
V
3, 8
ESD Protection Disable
Output Bias Current
1. a denotes a, b, c or d.
ESD
ESD
−9.2
−3.0
−9.0
−5.0
Vx_L
−10.0
V
6, 7, 10
1, 4, 5
VOUTa
I
mA
OUT
2. The maximum DC current is for one output. I = I
+ I . See Figure 27.
SS
DD
OUT
3. The operating value of the substrate voltage, V , will be marked on the shipping container for each device. The value of V is set such
AB
AB
that the photodiode charge capacity is the nominal P (see Specifications).
Ne
4. An output load sink must be applied to each VOUT pin to activate each output amplifier.
5. Nominal value required for 40 MHz operation per output. May be reduced for slower data rates and lower noise.
6. Adherence to the power-up and power-down sequence is critical. See Sequence section.
7. ESD maximum value must be less than or equal to V1_L + 0.4 V and V2_L + 0.4 V.
8. Refer to Application Note Using Interline CCD Image Sensors in High Intensity Visible Lighting Conditions.
−
9. 12.0 V may be used if the total output signal desired is 20,000 e or less.
10.Where Vx_L is the level set for V1_L, V2_L, V3_L, or V4_L in the application.
I
DD
HCCD
Floating
Diffusion
I
OUT
VOUTa
I
SS
Source
Follower
#1
Source
Follower
#2
Source
Follower
#3
Figure 27. Output Amplifier