Connections
I Terminal Arrangement
Note: 1. Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs.
2. Non-contact input is also available.
AC Models
H7HP-A
H7HP-C8
External power supply
12 VDC 50 mA max.
External power supply
12 VDC 50 mA max.
100 to 240 VAC
100 to 240 VAC
Power
supply
Power
supply
Power
supply
Power
supply
Unused Unused Unused 0 V
12 VDC
Unused Unused Unused
0 V
12 VDC
5
6
7
2
8
3
9
4
10
11
5
6
1
7
2
8
9
10
11
1
3
4
Key pro-
tection
input
Key pro-
tection
input
Count 1 Count 2
input or input or
start input gate input
Reset Count 1 Count 2
input
Reset
input
input
input
NPN mode
PNP mode
NPN mode
PNP mode
DC Models
H7HP-AD
H7HP-C8D
12 to 24 VDC
12 to 24 VDC
Power
supply
Power
supply
0 V
Unused Unused Unused Unused Unused
0 V
Unused Unused Unused Unused Unused
5
6
1
7
2
8
3
9
4
10
11
5
6
7
2
8
9
10
11
1
3
4
Key pro-
tection
input
Key pro-
tection
input
Count 1 Count 2
input or input or
start input gate input
Reset Count 1 Count 2
Reset
input
input
input
input
NPN mode
NPN mode
PNP mode
PNP mode
Operation
I DIP Switch Settings
Switches 1 to 4 are all set to OFF before shipping.
H7HP-C8/-C8D
Pin no.
Item
Unused
OFF
ON
1
---
---
2
3
4
Counting speed 30 Hz
Input mode (note) NPN
5 kHz
PNP
---
H7HP-A/-AD
Unused
---
Pin no.
Item
Function
OFF
ON
Time counter
5 kHz
Note: When the setting has been changed, turned power off and on
to continue. The display will show “0” when the power is turned
back on.
1
Total counter
2
Counting speed 30 Hz
Time range
99999.9 h
99 h 59 min 59 s
PNP
3
4
Input mode (note) NPN
Unused
---
---
C-54
Total Counter/Time Counter (DIN 72 x 36) H7HP