E2E
Diagram 12 E2E-X5MY@
Diagram 11 E2E-X2Y@
43
9
43
9
21 dia.
17
21 dia.
17
38
38
7
4
10
4
10
9 dia.
*
*
Operation indicator (red)
Two clamping nuts
Operation indicator (red)
Two clamping nuts
Toothed
washer
M12 × 1
M12 × 1
4-dia. vinyl-insulated round cable with 2
4-dia. vinyl-insulated round cable with 2
Toothed
washer
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Pre-wired Models (Shielded)
Mounting Hole Dimensions
Dimension
F (mm)
M8
M12
M18
M30
8.5+0.5 dia. 12.5+0.5 dia. 18.5+0.5 dia. 30.5+0.5 dia.
0 0 0 0
F
Diagram 13 E2E-X3T1
Pre-wired Models (Unshielded)
60
9
21 dia.
17
55
4
10
*1
Indicators *2
M12 × 1
Two clamping nuts
*1 4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Toothed
washer
*2 Operation indicator (red), Setting indicator (green)
Diagram 14 E2E-X7D@/E2E-X5E@/F@
E2E-X5Y@/E2E-X7T1
Diagram 15 E2E-X14MD@/E2E-X10ME@/F@
E2E-X10MY@
43
38
43
38
12
12
29 dia.
24
29 dia.
24
4
10
4
10
10
14.8 dia.
*1
*1
Indicators *2
*1
Indicators *2
M18 × 1
M18 × 1
Two clamping nuts
Toothed washer
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
Models with Highly Oil-resistant Cables:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.5
mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and
up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
31