E2E-X@E@/F@ DC 3-wire Models
Size
M8
M12
Unshielded
M18
Unshielded
M30
Unshielded
Type
Shielded
Unshielded
Shielded
Shielded
Shielded
E2E-X10ME@/
F@
E2E-X18ME@/
F@
Item
E2E-X1R5E@/ E2E-X2ME@/ E2E-X2E@/ E2E-X5ME@/ E2E-X5E@/
E2E-X10E@/
F@
F@
1.5 mm 10% 2 mm 10%
0 to 1.2 mm 0 to 1.6 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.)
F@
F@
F@
F@
Sensing distance
Set distance
2 mm 10%
0 to 1.6 mm
5 mm 10%
0 to 4.0 mm
5 mm 10%
0 to 4.0 mm
10 mm 10% 10 mm 10% 18 mm 10%
0 to 8.0 mm 0 to 8.0 mm 0 to 14.0 mm
Differential travel
Sensing object
Standard sensing
object
Iron, 8 x 8 x
1 mm
Iron, 12 x 12 x Iron, 12 x 12 x Iron, 15 x 15 x Iron, 18 x 18 x Iron, 30 x 30 x Iron, 30 x 30 x Iron, 54 x 54 x
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
Response speed (See 2.0 kHz
note 1.)
0.8 kHz
1.5 kHz
0.4 kHz
0.6 kHz
0.2 kHz
0.4 kHz
0.1 kHz
Power supply voltage
(operating voltage
range) (See note 2.)
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
Current consumption
13 mA max.
Control Load current 200 mA max.
output
(See note 2.)
Residual
voltage
2 V max. (Load current: 200 mA, Cable length: 2 m)
Indicator
Operation indicator (red LED)
Operation mode
(with sensing object
approaching)
E1 F1 Models: NO
E2 F2 Models: NC
For details, refer to Timing Charts.
Protection circuits
Power supply reverse polarity protection, surge suppressor, output load short-circuit protection
Ambient temperature
(See note 2)
Operating/Storage: –40°C to 85°C (with no icing or condensation)
Ambient humidity
Operating/Storage: 35% to 95% (with no icing)
Temperature influence
15% max. of sensing distance at 23°C in the temperature range of –40°C to 85°C
10% max. of sensing distance at 23°C in the temperature range of –25°C to 70°C
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
1% max. of sensing distance in the rated voltage range 15%
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times each in X, Y, 1,000 m/s2 10 times each in X, Y, and Z directions
and Z directions
Degree of protection
Connection method
IEC 60529 IP67 (Pre-wired models: in-house standard for oil resistance (former JEM standard equivalent to IP67g)) (See note
3.)
Pre-wired models (standard length 2 m), connector models
Weight
Pre-wired
Approx. 65 g
Approx. 75 g
Approx. 150 g
Approx. 40 g
Approx. 195 g
Approx. 90 g
(packed models
state)
Connector
Approx. 15 g
Approx. 25 g
models
Material Case
Stainless steel (SUS303)
Brass-nickel plated
Sensing
surface
PBT (polybutylene terephthalate)
Clamping
nuts
Brass-nickel plated
Toothed
washer
Iron-zinc plated
Accessories
Instruction manual
Note 1. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
2. When using an E2E with an M8 connector at an ambient temperature range between 70°C and 85°C, supply 10 to 30 VDC to the E2E and
make sure that the E2E has a control output of 100 mA maximum.
3. This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former JEM standard.
E2E/E2E2 Cylindrical Proximity Sensor
9