E2E-X@Y@ AC 2-wire Models
Size
M8
M12
Unshielded
E2E-X2MY@ E2E-X2Y@ E2E-X5MY@ E2E-X5Y@
M18
Unshielded
E2E-X10MY@
M30
Unshielded
E2E-X18MY@
Unshielded
Type
Shielded
E2E-X1R5Y@
Shielded
Shielded
Shielded
Item
E2E-X10Y@
Sensing distance
Set distance
1.5 mm 10% 2 mm 10% 2 mm 10% 5 mm 10% 5 mm 10% 10 mm 10% 10 mm 10% 18 mm 10%
0 to 1.2 mm 0 to 1.6 mm 0 to 1.6 mm 0 to 4.0 mm 0 to 4.0 mm 0 to 8.0 mm 0 to 8.0 mm 0 to 14.0 mm
10% max. of sensing distance
Differential travel
Sensing object
Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.)
Standard sensing
object
Iron, 8 x 8 x Iron,12 x 12 x Iron, 12 x 12 x Iron, 15 x 15 x Iron, 18 x 18 x Iron, 30 x 30 x Iron, 30 x 30 x Iron, 54 x 54 x
1 mm
25 Hz
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
Response speed
Power supply
voltage (operating
voltage range)
(See note 1.)
24 to 240 VAC, 50/60 Hz (20 to 264 VAC)
Leakage current
1.7 mA max.
Control Load
output current
(See note
5 to 100 mA
5 to 200 mA
5 to 300 mA
2.)
Residual
voltage
Refer to Engineering Data.
Indicator
Operation indicator (red LED)
Y1 Models: NO
Operation mode
(with sensing object Y2 Models: NC
approaching)
For details, refer to Timing Charts.
Surge suppressor
Protection circuit
Ambienttemperature Operating/Storage: –25°C to Operating/Storage: –40°C to 85°C (with no icing or condensation)
(See notes 1 and 2.) 70°C (with no icing or
condensation)
Ambient humidity
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
10% max. of sensing
distance at 23°C in the
temperature range of –25°C
to 70°C
15% max. of sensing distance at 23°C in the temperature range of –40°C to 85°C
10% max. of sensing distance at 23°C in the temperature range of –25°C to 70°C
Voltage influence
1% max. of sensing distance in the rated voltage range 15%
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
4,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case (2,000 VAC for M8 Models)
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times each in X, 1,000 m/s2 10 times each in X, Y, and Z directions
Y, and Z directions
Shock resistance
Degree of protection IEC 60529 IP67 (Pre-wired models: in-house standard for oil resistance (former JEM standard equivalent to IP67g)) (See
note 3.)
Connection method Pre-wired models (standard length 2 m), connector models
Weight Pre-wired
(packed models
state)
Approx. 60 g
Approx. 70 g
Approx. 130 g
Approx. 40 g
Approx. 175 g
Approx. 90 g
Connector Approx. 15 g
Approx. 25 g
models
Material Case
Stainless steel (SUS303)
Brass-nickel plated
Sensing
surface
PBT (polybutylene terephthalate)
Clamping
nuts
Brass-nickel plated
Iron-zinc plated
Toothed
washer
Accessories
Instruction manual
Note 1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25°C.
2. When using an M18-or M30-sized E2E within an ambient temperature of 70°C to 85°C, make sure that the E2E has a control output of 5
to 200 mA max.
3. This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former JEM standard.
E2E/E2E2 Cylindrical Proximity Sensor
11