Specifications
■ Ratings/Characteristics
E2E
E2E-X@D@ DC 2-wire Models
Size
M8
M12
Unshielded
M18
Unshielded
E2E-X7D@ E2E-X14MD@ E2E-X10D@ E2E-X20MD@
M30
Type
Shielded
E2E-X2D@
2 mm 10%
Unshielded
Shielded
E2E-X3D@
3 mm 10%
0 to 2.4 mm
Shielded
Shielded Unshielded
Item
E2E-X4MD@
4 mm 10%
0 to 3.2 mm
E2E-X8MD@
8 mm 10%
0 to 6.4 mm
Sensing distance
7 mm 10%
0 to 5.6 mm
14 mm 10% 10 mm 10% 20 mm 10%
0 to 11.2 mm 0 to 8.0 mm 0 to 16.0 mm
Set distance (See note 1.) 0 to 1.6 mm
Differential travel
Sensing object
15% max. of sensing distance 10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal, refer to Engineering Data.)
Standard sensing object Iron, 8 x 8 x
Iron, 20 x 20 x Iron,12 x 12 x Iron,30 x 30 x Iron, 18 x 18 x Iron, 30 x 30 x Iron,30 x 30 x Iron, 54 x 54 x
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
1 mm
Response speed (See
note 2.)
1.5 kHz
1.0 kHz
1.0 kHz
0.8 kHz
0.5 kHz
0.4 kHz
0.4 kHz
0.1 kHz
Power supply voltage
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
0.8 mA max.
(operating voltage range)
Leakage current
Control
output
Load
current
3 to 100 mA
Diagnostic output: 50 mA for -D1(5)S models
Residual
voltage
(See note 3.)
3 V max. (Load current: 100 mA, Cable length: 2 m. M1J-T models only: 5 V max.)
Indicator
D1 Models: Operation indicator (red LED), setting indicator (green LED)
D2 Models: Operation indicator (red LED)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
For details, refer to Timing Charts.
Diagnostic output delay 0.3 to 1 s
Protection circuits
Ambient temperature
Ambient humidity
Surge suppressor, output load short-circuit protection (for control and diagnostic output)
Operating: –25°C to 70°C, Storage: –40°C to 85°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
15% max. of sensing
distance at 23°C in the
temperature range of –25°C to
70°C
10% max. of sensing distance at 23°C in the temperature range of –25°C to 70°C
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
1% max. of sensing distance in the rated voltage range 15%
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
500 m/s2 10 times each in X, 1,000 m/s2 10 times each in X, Y, and Z directions
Y, and Z directions
Degree of protection
Connection method
IEC 60529 IP67 (Pre-wired models, pre-wired connector models: in-house standard for oil resistance (former JEM standard
equivalent to IP67g)) (See note 4.)
Pre-wired models (standard length: 2 m), connector models, pre-wired connector models (standard length: 0.3 m)
Weight
(packed
state)
Pre-wired
models
Approx. 60 g
Approx. 70 g
Approx. 130 g
Approx. 175 g
Pre-wired
connector
models
---
Approx. 40 g
Approx. 70 g
Approx. 110 g
Connector Approx. 15 g
models
Approx. 25 g
Approx. 40 g
Approx. 90 g
Material
Case
Stainless steel (SUS303)
Brass-nickel plated
Sensing
surface
PBT (polybutylene terephthalate)
Clamping
nuts
Brass-nickel plated
Iron-zinc plated
Toothed
washer
Accessories
Instruction manual
Note 1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 models).
2. The response speed is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard
sensing object, and a set distance of half the sensing distance.
3. The residual voltage of each E2E model with the model number suffix “-M1J-T” is 5 V. When connecting an E2E model with the suffix “-
M1J-T” to a device, make sure that the device can withstand the residual voltage.
4. This OMRON in-house standard confirms resistance to cutting and other oils. It is equivalent to the former JEM standard.
8
E2E/E2E2 Cylindrical Proximity Sensor