D4B-@N
Ratings
Non-inductive load (A)
Inductive load (A)
Inductive load Motor load
NC NO NO
Rated voltage (V)
Resistive load
NC NO
Lamp load
NC
NO
NC
125 VAC
250
400
10
10
10
3
2
1.5
1.5
1
0.8
10
10
3
5
3
1.5
2.5
1.5
0.8
8 VDC
14
30
10
10
6
6
6
4
3
3
3
10
10
6
6
6
4
125
250
0.8
0.4
0.2
0.1
0.2
0.1
0.8
0.4
0.2
0.1
Note: 1. The above values are continuous currents.
2. Inductive loads have a power factor of 0.4 or higher (AC) or a time constant of 7 ms or lower (DC).
3. Lamp loads have a inrush current of 10 times the normal current.
4. Motor loads have a inrush current of 6 times the normal current.
Inrush current
30 A max.
Characteristics
Degree of protection *1
IP67 (EN60947-5-1)
30,000,000 operations min. (snap-action)
10,000,000 operations min. (slow-action)
Mechanical
Electrical
Durability *2
500,000 operations min. (10 A resistive load at 250 VAC)
1 mm/s to 0.5 m/s
Operating speed
Mechanical
Electrical
120 operations/minute
Operating frequency
Contact resistance
30 operations/minute
25 mΩ max.
General load
Gold-clad contact 20 mA resistive load at 5 VAC
(N-level reference value)
180 mA resistive load at 5 VAC
Minimum applicable load *4
Rated insulation voltage (Ui)
Rated frequency
600 V (EN60947-5-1)
50/60 Hz
Protection against electric shock
Class I (with ground terminal)
3 (EN60947-5-1)
Pollution degree (operating environment)
Between terminals
of same polarity
2.5 kV (snap-action)/4 kV (slow-action)
Impulse withstand voltage Between terminals
4 kV (slow-action)
4 kV
(EN60947-5-1)
of different polarity
Between each
terminal and ground
100 MΩ min. (at 500 VDC) between terminals of the same polarity and between each
terminal and non-current-carrying part
Insulation resistance
2 × 2 mm min. (slow-action)
2 × 0.5 mm min. (snap-action)
Contact gap
Vibration resistance
Malfunction
Destruction
Malfunction
10 to 55 Hz, 0.75 mm single amplitude
1,000 m/s2 min.
300 m/s2 min.
Shock resistance
Conditional short-circuit current
Conventional enclosed thermal current (Ithe)
Ambient operating temperature
Ambient operating humidity
Weight
100 A (EN60947-5-1)
20 A (EN60947-5-1)
–40 to 80°C (with no icing) *3
95% max.
Approx. 250 g
Note: 1. The above values are initial values.
2. The above values may vary depending on the model. Consult your OMRON sales representative for details.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand.
*2. The durability is for an ambient temperature of 5 to 35°C and ambient humidity of 40% to 70%. For further conditions, consult your OMRON
sales representative.
*3. –20 to 80°C for the flexible-rod type.
*4. The above values may vary depending on switching frequency, environmental condition, and relativity level, consult your OMRON sales
representative.