8. Limiting values
Table 4.
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V)
Symbol
V
CC
I
IK
I
OK
I
O
I
CC
I
GND
T
stg
Parameter
supply voltage
input clamping current
output clamping current
output current
supply current
ground current
storage temperature
V
I
<
−0.5
V or V
I
> V
CC
+ 0.5 V
V
O
<
−0.5
V or V
O
> V
CC
+ 0.5 V
−0.5
V < V
O
< V
CC
+ 0.5 V
Conditions
Min
−0.5
-
-
-
-
−50
−65
Max
+7
±20
±20
±25
50
-
+150
Unit
V
mA
mA
mA
mA
mA
°C