DC and AC parameters
M58LT256JST, M58LT256JSB
Table 20. DC characteristics - currents
Symbol
Parameter
Test condition
Typ
Max
Unit
ILI
Input leakage current
Output leakage current
0 V ≤VIN ≤VDDQ
1
1
µA
µA
ILO
0 V ≤VOUT ≤VDDQ
Supply current
asynchronous Read (f=5 MHz)
E = VIL, G = VIH
13
15
mA
4 word
8 word
16
18
22
23
50
19
20
mA
mA
mA
mA
µA
IDD1
Supply current
synchronous read (f=52 MHz)
16 word
25
Continuous
RP = VSS 0.2 V
27
IDD2
IDD3
Supply current (reset)
110
E = VDD 0.2 V
K = VSS
Supply current (standby)
50
50
110
110
µA
µA
Supply current (automatic
standby)
IDD4
E = VIL, G = VIH
VPP = VPPH
VPP = VDD
35
35
35
35
50
50
50
50
mA
mA
mA
mA
Supply current (program)
Supply current (erase)
(1)
IDD5
VPP = VPPH
VPP = VDD
Program/erase in one bank,
asynchronous read in another
bank
48
65
mA
(1),
Supply current
IDD6
(2)
(dual operations)
Program/erase in one bank,
synchronous read (continuous
f=52 MHz) in another bank
58
50
77
mA
µA
Supply current program/ erase
suspended (standby)
E = VDD 0.2 V
K = VSS
(1)
IDD7
110
VPP = VPPH
VPP = VDD
8
22
5
mA
µA
mA
µA
µA
µA
VPP supply current (program)
0.2
8
(1)
IPP1
VPP = VPPH
22
5
VPP supply current (erase)
VPP = VDD
0.2
0.2
0.2
IPP2
VPP supply current (read)
VPP ≤VDD
VPP ≤VDD
5
(1)
IPP3
VPP supply current (standby)
5
1. Sampled only, not 100% tested.
2. VDD dual operation current is the sum of read and program or erase currents.
56/108