DC and AC parameters
M25PX64
10
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 13. Operating conditions
Symbol
Parameter
Min
Typ
Max
Unit
VCC
VPPH
TA
Supply voltage
2.7
8.5
3.6
9.5
85
V
V
Supply voltage on VPP pin for fast bulk erase mode
Ambient operating temperature
–40
°C
Ambient operating temperature for fast bulk erase
mode
TAVPP
15
25
35
°C
Table 14. AC measurement conditions
Symbol
Parameter
Min
Max
Unit
CL
Load capacitance
30
pF
ns
V
Input rise and fall times
5
Input pulse voltages
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
VCC / 2
Input timing reference voltages
Output timing reference voltages
V
V
Figure 29. AC measurement I/O waveform
Input levels
Input and output
timing reference levels
0.8V
CC
0.7V
CC
CC
0.3V
CC
0.5V
0.2V
CC
AI07455
(1)
Table 15. Capacitance
Symbol
CIN/OUT Input/output capacitance (DQ0/DQ1)
CIN Input capacitance (other pins)
Parameter
Test condition
Min
Max
Unit
VOUT = 0 V
VIN = 0 V
8
6
pF
pF
1. Sampled only, not 100% tested, at TA=25 °C and a frequency of 33 MHz.
56/66