M25PE40
DC and AC parameters
Table 17. DC characteristics
Test condition
Symbol
Parameter
Min.
Max.
Unit
(in addition to those in Table 14)
ILI
Input Leakage current
Output Leakage current
± 2
± 2
µA
µA
ILO
Standby current
(Standby and Reset modes)
ICC1
ICC2
S = VCC, VIN = VSS or VCC
50
µA
Deep Power-down current
S = VCC, VIN = VSS or VCC
C = 0.1VCC/0.9.VCC at 25 MHz, Q = open
C = 0.1VCC/0.9.VCC at 50 MHz, Q = open
S = VCC
10
µA
mA
mA
mA
mA
V
6
8
Operating current
(FAST_READ)
ICC3
ICC4
ICC5
VIL
Operating current (PW)
Operating current (SE)
Input Low voltage
15
S = VCC
15
– 0.5
0.3VCC
VIH
Input High voltage
0.7VCC VCC+0.4
0.4
V
VOL
VOH
Output Low voltage
Output High voltage
IOL = 1.6 mA
V
IOH = –100 µA
VCC–0.2
V
(1)
Table 18.
Symbol
DC characteristics (75 MHz operation, T9HX (0.11 µm) process)
Test condition
Parameter
Min.
Max.
Unit
(in addition to those in Table 14)
ILI
Input Leakage current
Output Leakage current
± 2
± 2
µA
µA
ILO
Standby current
ICC1
ICC2
S = VCC, VIN = VSS or VCC
(Standby and Reset modes)
50
µA
Deep Power-down current
S = VCC, VIN = VSS or VCC
C = 0.1VCC/0.9.VCC at 33 MHz, Q = open
C = 0.1VCC/0.9.VCC at 75 MHz, Q = open
S = VCC
10
4
µA
mA
mA
mA
mA
V
Operating current
(FAST_READ)
ICC3
12
ICC4
ICC5
VIL
Operating current (PW)
Operating current (SE)
Input Low voltage
15
S = VCC
15
– 0.5
0.3VCC
VIH
Input High voltage
0.7VCC VCC+0.4
0.4
V
VOL
VOH
Output Low voltage
Output High voltage
IOL = 1.6 mA
V
IOH = –100 µA
VCC–0.2
V
1. Delivery of parts operating with a maximum clock rate of 75 MHz starts from week 8 of 2008.
47/62