M29FxxxFT, M29FxxxFB
DC and AC Parameters
7
DC and AC Parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions shown here.
Designers should check that the operating conditions in their circuit match the operating
conditions when relying on the quoted parameters.
Table 12. Operating and AC Measurement Conditions
Parameter
Min
Max
Unit
VCC Supply Voltage
4.5
–40
30
5.5
125
30
5
V
Ambient Operating Temperature
Load Capacitance (CL)
°C
pF
ns
V
Input Rise and Fall Times
Input Pulse Voltages
—
0 to VCC
VCC/2
0 to VCC
VCC/2
Input and Output Timing Ref. Voltages
V
Figure 18. AC Measurement I/O Waveform
V
CC
V
/2
CC
0V
AI04498
Figure 19. AC Measurement Load Circuit
V
V
CC
CC
25kΩ
DEVICE
UNDER
TEST
25kΩ
0.1µF
C
L
AI04499
C
includes JIG capacitance
L