Integrated Functions (Continued)  
Table 4-32. Display Controller Timing Registers (Continued)  
Bit  
Name  
Description  
10:0  
V_BLANK_  
START  
Vertical Blank Start: This field represents the line at which the vertical blanking signal becomes  
active minus 1. If the display is interlaced, this value should be programmed to V_ACTIVE plus 1.  
Note: All values are specified in lines. For interlaced display, no border is supported, so blank timing is implied by the total/active tim-  
ing.  
GX_BASE+8348h-834Bh  
DC_V_TIMING_3 Register (R/W)  
Reserved: Set to 0.  
Default Value = xxxxxxxxh  
31:27  
26:16  
RSVD  
V_SYNC_END  
Vertical Sync End: This field represents the line at which the CRT vertical sync signal becomes  
inactive minus 1.  
15:11  
10:0  
RSVD  
Reserved: Set to 0.  
V_SYNC_START Vertical Sync Start: This field represents the line at which the CRT vertical sync signal becomes  
active minus 1. For interlaced display, note that the vertical counter is incremented twice during each  
line and since there are an odd number of lines, the vertical sync pulse will trigger in the middle of a  
line for one field and at the end of a line for the subsequent field.  
Note: All values are specified in lines.  
GX_BASE+834Ch-834Fh  
DC_FP_V_TIMING Register (R/W)  
Reserved: Set to 0.  
Default Value = xxxxxxxxh  
31:27  
26:16  
RSVD  
FP_V_SYNC  
_END  
Flat Panel Vertical Sync End: This field represents the line at which the flat panel vertical sync sig-  
nal becomes inactive minus 2. Note that the internal flat panel vertical sync is latched by the flat  
panel horizontal sync prior to being output to the panel.  
15:11  
10:0  
RSVD  
Reserved: Set to 0.  
FP_VSYNC  
_START  
Flat Panel Vertical Sync Start: This field represents the line at which the internal flat panel vertical  
sync signal becomes active minus 2. Note that the internal flat panel vertical sync is latched by the  
flat panel horizontal sync prior to being output to the panel.  
Note: All values are specified in lines.  