LM1117I Electrical Characteristics
Typicals and limits appearing in normal type apply for TJ = 25˚C. Limits appearing in Boldface type apply over the entire junc-
tion temperature range for operation, −40˚C to 125˚C.
Min
(Note 5)
Typ
(Note 4)
Max
(Note 5)
Symbol
Parameter
Conditions
Units
VREF
Reference Voltage
LM1117I-ADJ
IOUT = 10mA, VIN-VOUT = 2V, TJ = 25˚C
10mA ≤ IOUT ≤ 800mA, 1.4V ≤ VIN-VOUT
≤ 10V
1.238
1.250
1.250
1.262
V
V
1.200
1.290
VOUT
∆VOUT
∆VOUT
Output Voltage
LM1117I-3.3
IOUT = 10mA, VIN = 5V, TJ = 25˚C
0 ≤ IOUT ≤ 800mA, 4.75V ≤ VIN ≤ 10V
LM1117I-5.0
3.267
3.300
3.300
3.333
V
V
3.168
3.432
IOUT = 10mA, VIN = 7V, TJ = 25˚C
0 ≤ IOUT ≤ 800mA, 6.5V ≤ VIN ≤ 12V
LM1117I-ADJ
4.950
5.000
5.000
5.050
V
V
4.800
5.200
Line Regulation
(Note 6)
IOUT = 10mA, 1.5V ≤ VIN-VOUT ≤ 13.75V
LM1117I-3.3
0.035
0.3
10
%
IOUT = 0mA, 4.75V ≤ VIN ≤ 15V
LM1117I-5.0
1
1
mV
mV
%
IOUT = 0mA, 6.5V ≤ VIN ≤ 15V
LM1117I-ADJ
15
Load Regulation
(Note 6)
VIN-VOUT = 3V, 10 ≤ IOUT ≤ 800mA
LM1117I-3.3
0.2
1
0.5
15
VIN = 4.75V, 0 ≤ IOUT ≤ 800mA
LM1117I-5.0
mV
VIN = 6.5V, 0 ≤ IOUT ≤ 800mA
IOUT = 100mA
1
20
mV
V
V
IN-V OUT Dropout Voltage
1.10
1.15
1.20
1200
1.30
1.35
1.40
1500
(Note 7)
IOUT = 500mA
V
IOUT = 800mA
V
ILIMIT
Current Limit
VIN-VOUT = 5V, TJ = 25˚C
LM1117I-ADJ
800
mA
Minimum Load
Current (Note 8)
Quiescent Current
VIN = 15V
1.7
5
5
mA
mA
LM1117I-3.3
VIN ≤ 15V
15
LM1117I-5.0
VIN ≤ 15V
5
15
mA
%/W
dB
Thermal Regulation
Ripple Regulation
TA = 25˚C, 30ms Pulse
fRIPPLE =1 20Hz, VIN-VOUT = 3V VRIPPLE
= 1VPP
0.01
75
0.1
60
Adjust Pin Current
Adjust Pin Current
Change
60
120
10
µA
10 ≤ IOUT≤ 800mA,
1.4V ≤ VIN-VOUT ≤ 10V
0.2
0.5
µA
%
Temperature Stability
Long Term Stability
RMS Output Noise
Thermal Resistance
Junction-to-Case
TA = 125˚C, 1000Hrs
0.3
%
(% of VOUT), 10Hz ≤ f ≤10kHz
3-Lead SOT-223
0.003
15.0
10
%
˚C/W
˚C/W
˚C/W
˚C/W
˚C/W
3-Lead TO-252
Thermal Resistance
Junction-to-Ambient
No air flow)
3-Lead SOT-223 (No heat sink)
3-Lead TO-252 (No heat sink)(Note 9)
8-Lead LLP(Note 10)
136
92
40
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test conditions, see the Electrical Characteristics.
www.national.com
6