5026 series
SPECIFICATIONS
Absolute Maximum Ratings
V
= 0V
SS
Parameter
Symbol
Condition
Rating
Unit
V
Supply voltage range
Input voltage range
V
−0.5 to +7.0
DD
V
−0.5 to V + 0.5
DD
V
IN
Output voltage range
Operating temperature range
Storage temperature range
Output current
V
−0.5 to V + 0.5
DD
V
OUT
T
−40 to +85
−65 to +150
20
°C
°C
mA
opr
T
STG
I
OUT
Recommended Operating Conditions
V
= 0V
SS
Rating
Parameter
Symbol
Condition
Unit
min
2.25
2.25
2.25
2.25
2.25
2.25
typ
–
max
3.6
3.6
3.6
3.6
3.6
3.6
5026AL×
5026BL1
5026MLA
5026MLB
CL ≤ 30pF
V
V
CL ≤ 30pF
–
f ≤ 80MHz, CL ≤ 30pF
f ≤ 100MHz, CL ≤ 30pF
f ≤ 100MHz, CL ≤ 30pF
f ≤ 133MHz, CL ≤ 15pF
–
V
Operating supply voltage
V
DD
–
V
–
V
5026MLC
–
V
Input voltage
V
V
–
V
V
IN
SS
DD
Operating temperature
T
−40
20
20
–
+85
50
°C
MHz
MHz
MHz
MHz
MHz
OPR
5026AL×
–
*2
5026BL1
5026MLA
5026MLB
–
100
80
*1
Operating frequency
f
70
–
O
*2
*2
80
–
100
133
5026MLC
90
–
*1. The operating frequency is a yardstick value derived from the crystal used for NPC characteristics authentication. However, the oscillator frequency
band is not guaranteed. Specifically, the characteristics can vary greatly due to crystal characteristics and mounting conditions, so the oscillation char-
acteristics of components must be carefully evaluated.
*2. When 2.5V operation, the ratings of switching characteristics are difference by the frequency or output load. Refer to “Switching Characteristics”.
SEIKO NPC CORPORATION —4