74HC4511; 74HCT4511
Nexperia
BCD to 7-segment latch/decoder/driver
Table 7.
Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); CL = 50 pF unless otherwise specified; for test circuit see Figure 12.
Symbol Parameter Conditions
25 C
40 C to +85 C 40 C to +125 C Unit
Min Typ Max
Min
Max
Min
Max
th
hold time
A-D to LE; see Figure 11
VCC = 2.0 V
0
0
0
-
11
4
-
-
-
-
0
0
0
-
-
-
0
0
0
-
-
-
-
-
ns
ns
ns
pF
VCC = 4.5 V
VCC = 6.0 V
3
[3]
[1]
CPD
power
VI = GND to VCC; VCC = 5 V;
dissipation fi = 1 MHz
capacitance
64
-
74HCT4511
tpd propagation A-D to a-g; see Figure 8
delay
VCC = 4.5 V
-
-
28
24
60
-
-
-
75
-
-
-
90
-
ns
ns
VCC = 5.0 V; CL = 15 pF
LE to a-g; see Figure 9
VCC = 4.5 V
-
-
27
24
54
-
-
-
68
-
-
-
81
-
ns
ns
VCC = 5.0 V; CL = 15 pF
BI to a-g; see Figure 10
VCC = 4.5 V
-
-
23
20
44
-
-
-
55
-
-
-
66
-
ns
ns
VCC = 5.0 V; CL = 15 pF
LT to a-g; see Figure 8
VCC = 4.5 V
-
-
16
13
30
-
-
-
38
-
-
-
45
-
ns
ns
VCC = 5.0 V; CL = 15 pF
[2]
tt
transition
time
see Figure 8, Figure 9 and
Figure 10
VCC = 4.5 V
-
7
5
5
15
-
-
19
-
-
22
-
ns
ns
ns
tW
pulse width LE LOW; see Figure 9
VCC = 4.5 V
16
12
20
15
24
18
tsu
set-up time A-D to LE; see Figure 11
VCC = 4.5 V
-
-
-
th
hold time
A-D to LE; see Figure 11
VCC = 4.5 V
0
-
4
-
-
0
-
-
-
0
-
-
-
ns
[3]
CPD
power
VI = GND to VCC 1.5 V;
64
pF
dissipation
capacitance
VCC = 5 V; fi = 1 MHz
[1] tpd is the same as tPHL and tPLH
.
[2] tt is the same as tTHL and tTLH
.
[3] CPD is used to determine the dynamic power dissipation (PD in W):
PD = CPD VCC2 fi N + (CL VCC2 fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
(CL VCC2 fo) = sum of outputs.
74HC_HCT4511
All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2017. All rights reserved
Product data sheet
Rev. 3 — 15 November 2016